Views

Difference between revisions of "Power supply and PoE classes"

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Jump to: navigation, search
(Phones)
m (Phones)
Line 6: Line 6:
  
 
{| {{DefaultTable}}
 
{| {{DefaultTable}}
! rowspan="2" width="120" | Name of Phone
+
! rowspan="2" width="120" | Phone model
! rowspan="2" | Key Modules
+
! rowspan="2" valign="middle" | Key Modules
! colspan="3" | Power over Ethernet
+
! colspan="3" valign="middle" | Power over Ethernet
! rowspan="2" | External<br />Power Unit<ref name="pscable">The external power supply includes the power supply device and one RJ10 cable. Use the cable to connect the digital port on the power supply device with the corresponding power port on the phone!</ref>
+
! rowspan="2" valign="middle" | External<br />Power Unit<ref name="pscable">The external power supply includes the power supply device and one RJ10 cable. Use the cable to connect the digital port on the power supply device with the corresponding power port on the phone!</ref>
 
|-
 
|-
! [[PoE|Class 1]]
+
! valign="middle" |[[PoE|Class 1]]
! [[PoE|Class 2]]
+
! valign="middle" |[[PoE|Class 2]]
! [[PoE|Class 3]]
+
! valign="middle" |[[PoE|Class 3]]
 
|-
 
|-
 
| OpenStage 20
 
| OpenStage 20
| -
+
| valign="middle" |-
| {{yes}}
+
| valign="middle" |{{yes}}
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
 
|-
 
|-
 
| OpenStage 20 G
 
| OpenStage 20 G
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| {{yes}}
+
| valign="middle" | {{yes}}
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
 
|-
 
|-
 
| OpenStage 20 T
 
| OpenStage 20 T
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
 
|-
 
|-
 
| OpenStage 40
 
| OpenStage 40
| 0, 1 or 2
+
| valign="middle" |0, 1 or 2
| -
+
| valign="middle" |-
| {{yes}}
+
| valign="middle" |{{yes}}
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
 
|-
 
|-
 
| OpenStage 40 G
 
| OpenStage 40 G
| 0, 1 or 2
+
| valign="middle" |0, 1 or 2
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| {{yes}}
+
| valign="middle" |{{yes}}
| -
+
| valign="middle" |-
 
|-
 
|-
 
| rowspan="2" valign="middle" | OpenStage 40 T
 
| rowspan="2" valign="middle" | OpenStage 40 T
| 0
+
| valign="middle" |0
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
 
|-
 
|-
| 1 or 2
+
| valign="middle" |1 or 2
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
 
| {{yes}}
 
| {{yes}}
 
|-
 
|-
 
| OpenStage 60/80
 
| OpenStage 60/80
| 0, 1 or 2
+
| valign="middle" |0, 1 or 2
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| {{yes}}
+
| valign="middle" |{{yes}}
| -
+
| valign="middle" |-
 
|-
 
|-
 
| rowspan="2" valign="middle" | OpenStage 60/80 G
 
| rowspan="2" valign="middle" | OpenStage 60/80 G
| 0 or 1
+
| valign="middle" |0 or 1
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| {{yes}}
+
| valign="middle" |{{yes}}
| -
+
| valign="middle" |-
 
|-
 
|-
| 2
+
| valign="middle" |2
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| {{yes}}
+
| valign="middle" |{{yes}}
 
|-
 
|-
 
| OpenStage 60/80 T
 
| OpenStage 60/80 T
| 0, 1 or 2
+
| valign="middle" |0, 1 or 2
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| -
+
| valign="middle" |-
| {{yes}}
+
| valign="middle" |{{yes}}
 +
|-
 
|}
 
|}
 
<references />
 
<references />

Revision as of 06:46, 25 June 2008

The tables below show the required power supply of OpenStage phones and accessories if Power over Ethernet (PoE) is available.

Phones

Connection from the external power supply to the phone
Power connection on the phone (left hand side)
Phone model Key Modules Power over Ethernet External
Power Unit[1]
Class 1 Class 2 Class 3
OpenStage 20 - tick.gif - - -
OpenStage 20 G - - tick.gif - -
OpenStage 20 T - - - - -
OpenStage 40 0, 1 or 2 - tick.gif - -
OpenStage 40 G 0, 1 or 2 - - tick.gif -
OpenStage 40 T 0 - - - -
1 or 2 - - - tick.gif
OpenStage 60/80 0, 1 or 2 - - tick.gif -
OpenStage 60/80 G 0 or 1 - - tick.gif -
2 - - - tick.gif
OpenStage 60/80 T 0, 1 or 2 - - - tick.gif
  1. The external power supply includes the power supply device and one RJ10 cable. Use the cable to connect the digital port on the power supply device with the corresponding power port on the phone!

Accessories

Accessory External Power Unit
OpenStage Phone Adapter tick.gif
OpenStage BLF tick.gif

See also

Show SIP related | Show HFA related | Show TDM related