Views

Difference between revisions of "Power supply and PoE classes"

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Jump to: navigation, search
(Power Provision Matrix)
Line 129: Line 129:
 
|}
 
|}
  
Power supply information are also available for the [[OpenStage Phone Adapter]].
+
The [[OpenStage Phone Adapter]] needs also an external power supply.
  
 
== Examples ==
 
== Examples ==

Revision as of 12:59, 21 July 2008

Construction.png This article or section is currently under construction. In order to avoid editing conflicts, please wait until this message is removed or contact the author (Horemu 17:20, 18 July 2008 (CEST)).

The tables below show the required power supply of OpenStage phones and accessories if Power over Ethernet (PoE) is available.

Power Provision Matrix

Device ... with
Key Modules
Power over Ethernet External
Power Unit
Class 1 Class 2 Class 3
OpenStage 20 - tick.gif tick.gif tick.gif tick.gif os20-p.jpg
OpenStage 20 G - - tick.gif tick.gif tick.gif
OpenStage 20 T - - - - -
OpenStage 40 0, 1 or 2 - - tick.gif tick.gif os40-p.jpg
OpenStage 40 G 0, 1 or 2 - - tick.gif tick.gif
OpenStage 40 T 0 - - - -
1 or 2 - - - tick.gif
OpenStage 60 0, 1 or 2 - - tick.gif tick.gif os60-p.jpg
OpenStage 60 G 0 or 1 - - tick.gif tick.gif
2 - - - tick.gif
OpenStage 60 T 0, 1 or 2 - - - tick.gif
OpenStage 80 0, 1 or 2 - - tick.gif tick.gif os80-p.jpg
OpenStage 80 G 0 or 1 - - tick.gif tick.gif
2 - - - tick.gif
OpenStage 80 T 0, 1 or 2 - - - tick.gif
OpenStage BLF - - - - tick.gif

The OpenStage Phone Adapter needs also an external power supply.

Examples

You have an OpenStage 20 G:

The telephone needs PoE Class 2 or above or an external power unit.

You have an OpenStage 40 with an OpenStage Busy Lamp Field 40:

The telephone needs PoE Class 3 or above or an external power unit.
The OpenStage BLF needs a separate external power unit.

You have an OpenStage 40 T:

The telephone does not need any additional provision of electricity.

You have one OpenStage 80 G with two OpenStage Key Module 80:

The telephone needs an external power unit.
The Key Modules do not need any additional provision of electricity.

Power Supplies

Order No. Usage Region Design
L30250-F600-C141 OpenStage family, optiPoint family EU switched-mode
L30250-F600-C142 OpenStage family, optiPoint family UK switched-mode
L30250-F600-C143 OpenStage family, optiPoint family US switched-mode
L30250-F600-A158 optiPoint 500 telephones EU linear regulator
L30252-F600-A580 optiPoint 500 telephones UK linear regulator
L30250-F600-A580 optiPoint 500 telephones US linear regulator

See also