Line 12: Line 12:
 
! valign="middle" | Class 2
 
! valign="middle" | Class 2
 
! valign="middle" | Class 3
 
! valign="middle" | Class 3
 +
|- style="background-color:#f0f0f0;"
 +
| [[OpenStage 10 T]]
 +
| valign="middle" |-
 +
| valign="middle" |-
 +
| valign="middle" |-
 +
| valign="middle" |-
 +
| valign="middle" |-
 
|- style="background-color:#e0e0e0;"  
 
|- style="background-color:#e0e0e0;"  
| [[OpenStage 10 T]]
+
| rowspan="2" valign="middle" | [[OpenStage 15 T]]
 +
| valign="middle" | 0
 +
| valign="middle" |-
 +
| valign="middle" |-
 
| valign="middle" |-
 
| valign="middle" |-
 
| valign="middle" |-
 
| valign="middle" |-
 +
| rowspan="2" valign="middle" style="background-color:#ffffff;" | [[Image:os15-p.jpg|75px]]
 +
|- style="background-color:#e0e0e0;"
 +
| valign="middle" | 1
 
| valign="middle" |-
 
| valign="middle" |-
 
| valign="middle" |-
 
| valign="middle" |-
 
| valign="middle" |-
 
| valign="middle" |-
 +
| valign="middle" | {{yes}}
 
|- style="background-color:#f0f0f0;"  
 
|- style="background-color:#f0f0f0;"  
 
| [[OpenStage 20 E]]
 
| [[OpenStage 20 E]]
Line 26: Line 40:
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
| rowspan="4" valign="middle" style="background-color:#ffffff;" | [[Image:os20-p.jpg|100px]]
+
| rowspan="4" valign="middle" style="background-color:#ffffff;" | [[Image:os20-p.jpg|80px]]
 
|- style="background-color:#f0f0f0;"  
 
|- style="background-color:#f0f0f0;"  
 
| [[OpenStage 20]]
 
| [[OpenStage 20]]
Line 55: Line 69:
 
| valign="middle" | {{yes}}  
 
| valign="middle" | {{yes}}  
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
| rowspan="4" valign="middle" style="background-color:#ffffff;" | [[Image:os40-p.jpg|100px]]
+
| rowspan="4" valign="middle" style="background-color:#ffffff;" | [[Image:os40-p.jpg|85px]]
 
|- style="background-color:#e0e0e0;"  
 
|- style="background-color:#e0e0e0;"  
 
| [[OpenStage 40 G]]
 
| [[OpenStage 40 G]]
Line 83: Line 97:
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
| rowspan="4" valign="middle" style="background-color:#ffffff;" | [[Image:os60-p.jpg|100px]]
+
| rowspan="4" valign="middle" style="background-color:#ffffff;" | [[Image:os60-p.jpg|85px]]
 
|- style="background-color:#f0f0f0;"  
 
|- style="background-color:#f0f0f0;"  
 
| rowspan="2" valign="middle" | [[OpenStage 60 G]]
 
| rowspan="2" valign="middle" | [[OpenStage 60 G]]
Line 111: Line 125:
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
 
| valign="middle" | {{yes}}
| rowspan="4" valign="middle" style="background-color:#ffffff;" | [[Image:os80-p.jpg|100px]]
+
| rowspan="4" valign="middle" style="background-color:#ffffff;" | [[Image:os80-p.jpg|90px]]
 
|- style="background-color:#e0e0e0;"  
 
|- style="background-color:#e0e0e0;"  
 
| rowspan="2" valign="middle" | [[OpenStage 80 G]]
 
| rowspan="2" valign="middle" | [[OpenStage 80 G]]

Revision as of 14:31, 6 March 2009

The table below shows the required power provision of OpenStage phones and accessories.

Power Provision Matrix

Device ... with
Key Modules
Power over Ethernet External
Power Unit
Class 1 Class 2 Class 3
OpenStage 10 T - - - - -
OpenStage 15 T 0 - - - - os15-p.jpg
1 - - - tick.gif
OpenStage 20 E - tick.gif tick.gif tick.gif tick.gif os20-p.jpg
OpenStage 20 - tick.gif tick.gif tick.gif tick.gif
OpenStage 20 G - - tick.gif tick.gif tick.gif
OpenStage 20 T - - - - -
OpenStage 40 0, 1 or 2 - tick.gif tick.gif tick.gif os40-p.jpg
OpenStage 40 G 0, 1 or 2 - tick.gif tick.gif tick.gif
OpenStage 40 T 0 - - - -
1 or 2 - - - tick.gif
OpenStage 60 0, 1 or 2 - - tick.gif tick.gif os60-p.jpg
OpenStage 60 G 0 or 1 - - tick.gif tick.gif
2 - - - tick.gif
OpenStage 60 T 0, 1 or 2 - - - tick.gif
OpenStage 80 0, 1 or 2 - - tick.gif tick.gif os80-p.jpg
OpenStage 80 G 0 or 1 - - tick.gif tick.gif
2 - - - tick.gif
OpenStage 80 T 0, 1 or 2 - - - tick.gif
OpenStage BLF - - - - tick.gif

The OpenStage Phone Adapter needs also an external power supply.

Examples

You have an OpenStage 20:

The telephone needs PoE Class 1 or above or an external power unit.

You have an OpenStage 40 with an OpenStage Busy Lamp Field 40:

The telephone needs PoE Class 2 or above or an external power unit.
The OpenStage BLF needs a separate external power unit.

You have an OpenStage 40 T:

The telephone does not need any additional provision of electricity.

You have an OpenStage 80 G with two OpenStage Key Module 80:

The telephone needs an external power unit.
The Key Modules do not need any additional provision of electricity.

Power Supplies

Usage Region Design[1] Order No.
OpenStage family, optiPoint family EU SMPS L30250-F600-C141
OpenStage family, optiPoint family UK SMPS L30250-F600-C142
OpenStage family, optiPoint family US SMPS L30250-F600-C143
optiPoint 500 telephones EU linear L30250-F600-A158
optiPoint 500 telephones UK linear L30252-F600-A580
optiPoint 500 telephones US linear L30250-F600-A580

Wiring

Power provision for an IP telephone in a LAN with PoE. OS-POE.png

Power provision for an IP telephone in a LAN without PoE. OS-Supply-IP.png

Power provision for a TDM telephone (if necessary - see TDM phones in the Matrix table). OS-Supply-TDM.png