How to access XML applications
The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.
Please visit Devices to get further information about the current product portfolio.
How to configure your phone and how to access XML applications with an optiPoint application module or optiPoint display module.
For exploring the XML capabilities you don't have to necessarily set up your own webserver. Just try out one of the XML application samples, residing on one of our public internet servers. |
Contents
Prerequisites
- optiPoint 410 standard/ advance or optiPoint 420 standard/ advance with XML enabled Software in HFA environment
- optiPoint application module or optiPoint display module must be connected to the telephone
- Web-Browser on a LAN-integrated PC
Download XML enabled phone SW
Using XML on your Siemens IP phone requires a CorNet IP Software starting with V5.1.34. CorNet IP provides encryption capabilities. Hence its distribution must follow legal requirements which do not allow unrestricted SW distribution via the Internet. The firmware is only provided by Siemens technicians or by official Siemens Partners. Customers with self-care contracts will have access to Software within the Partner Portal Web portal (login required)
Another option is to register as "Open Developer" at the Technology Partner Website to get XML-enabled phone-SW.
To download the software see Software update optiPoint 410/420 or consult the Administration Manual optiPoint 410-420 family.
Configure applications using web-based management
- Obtain the IP-address of your phone.
- Start your web browser and access phone's web-based management by entering
https://###.###.###.###
(IP-address of your phone). - Follow the link:
Administration
> Enter administrator password (Default: 123456) >Applications
.
- Select
XML Applications
.
- Select
New program
to configure a new application.
- Set the appropriate parameters in the
New Program
form:
Parameter | Description | Comment |
---|---|---|
Display Name | The name of the program as it appears in the program menu on the optiPoint application module. | e.g. Warehouse Monitor
|
Application Name | This is used internally by the application to identify the program running on the telephone | e.g. BusinessAppOne
|
Server Address | The IP address or domain/host name of the server that provides the application or the XML document. | |
Server Port number | The number of the port that the server uses to provide the application or the XML document. | Standard http-port is used. |
Program Name on Server | The relative path to the servlet or to the first XML page of the application on the server. | e.g. cgi-bin/ippApp/Start.xml
|
Use Proxy | This specifies whether a Proxy should be used. |
|
Debug Mode | For applications developers only. | Don't change. |
Debug Program On Server | For applications developers only. | Don't change. |
- Click
Create Program
to start generating the program.