== Configure applications using web-based management ==
 
== Configure applications using web-based management ==
  
* Obtain the IP-address of your optiPoint 410/420.
+
* Obtain the IP-address of your phone.
 
* Start your web browser and access phone's web-based management by entering <code>https://###.###.###.###</code> (IP-address of your phone).
 
* Start your web browser and access phone's web-based management by entering <code>https://###.###.###.###</code> (IP-address of your phone).
* Follow the link: ''Administration'' > Enter Adminpassword (Default: 123456) > ''Applications'' > ''XML Applications'' (see screen below).
+
* Follow the link: <code>Administration</code> > Enter administrator password (Default: 123456) > <code>Applications</code>.
 +
[[image:Screenshot WBM oP410 XML1.gif|thumb|WBM screenshot ''Applications''|100px]]
 +
* Select <code>XML Applications</code>.
 +
[[image:Screenshot WBM oP410 XML2.gif|thumb|WBM screenshot ''XML Applications''|100px]]
 +
* Select <code>New program</code> to configure a new application.
 +
[[image:Screenshot WBM oP410 XML3.gif|thumb|WBM screenshot ''New Program''|100px]]
 +
* Set the appropriate parameters in the <code>New Program</code> form:
  
[[image:Screenshot WBM oP410 XML1.gif|thumb|WBM screenshot XML applications|left|150px]]
+
{{fixme|  
<br clear='left'>
+
Please add example entries, and how can I get these informations when I'm a user.  
 
+
|[[User:Martina.ganzer|Martina.ganzer]] 16:59, 23 January 2007 (CET)}}
* Select ''New program'' to configure a new application.
 
 
 
[[image:Screenshot WBM oP410 XML2.gif|thumb|WBM screenshot XML applications > New|left|150px]]
 
<br clear='left'>
 
 
 
* Set the appropriate parameters in the ''New Program'' form.
 
 
 
[[image:Screenshot WBM oP410 XML3.gif|thumb|WBM screenshot XML applications > Settings|left|150px]]
 
<br clear='left'>
 
 
 
For settings please refer to {{File-DL|XML developers guide|pdf}}.
 
  
 
{| {{DefaultTable}}
 
{| {{DefaultTable}}
 
! Parameter
 
! Parameter
! Value
+
! Description
 
! Comment
 
! Comment
 
|-
 
|-
 
| Display Name  
 
| Display Name  
| <a name of your choice to start application on your APM screen>
+
| The name of the program as it appears in the program menu on the optiPoint application module.
| length
+
| <code>???</code>
 
|-
 
|-
 
| Application Name
 
| Application Name
|  
+
| This is used internally by the application to identify the program running on the telephone
| t.b.d.
+
| <code>???</code>
 
|-
 
|-
 
| Server Address
 
| Server Address
| testfloor.selfip.org
+
| The IP address or domain/host name of the server that provides the application or the XML document.
| This is the server name, where demo apps reside
+
|  
 
|-
 
|-
 
| Server Port number
 
| Server Port number
| 80
+
| The number of the port that the server uses to provide the application or the XML document.
| Standard http-port is used
+
| Standard http-port is used.
 
|-
 
|-
| Program name on Server  
+
| Program Name on Server  
| xml/program_name.xml
+
| The relative path to the servlet or to the first XML page of the application on the server.
| all files reside in sub-dir: xml
+
| <code>???</code>
 
|-
 
|-
 
| Use Proxy
 
| Use Proxy
| Yes
+
| This specifies whether a [[Proxy]] should be used.
| Yes: if you are connected via a proxy to the internet. This will be mostly the case in enterprises. [[Configuring a Java/XML proxy|How to: proxy configuration]] <br> Noif your accessing the internet w/o Proxy
+
|  
 +
* <code>Yes</code> if you are connected via a Proxy to the internet. This will be mostly the case in enterprises.
 +
* <code>No</code> if your accessing the internet without a Proxy.
 
|-
 
|-
 
| Debug Mode
 
| Debug Mode
| Disabled
+
| For applications developers only.
| for applications developers only
+
| Don't change.
 
|-
 
|-
 
| Debug Program On Server
 
| Debug Program On Server
| empty
+
| For applications developers only.
| for applications developers only
+
| Don't change.
 
|}
 
|}
# Click '''Create Program''' to start generating the program.
+
* Click <code>Create Program</code> to start generating the program.
 +
 
 +
For settings please refer to {{File-DL|XML developers guide|pdf}}.
  
 
== XML Tutorial ==
 
== XML Tutorial ==

Revision as of 15:59, 23 January 2007

Construction.png This article or section is currently under construction. In order to avoid editing conflicts, please wait until this message is removed or contact the author (Martina.ganzer 15:35, 23 January 2007 (CET)).

How to configure your phone and how to access sample XML applications is the scope of this article. For exploring the XML capabilities of the optiPoint application module you do not necessarily set up your own webserver. Just try out one of the application samples, residing on one of our public internet servers.

Download XML enabled phone SW

Using XML on your Siemens IP-phone requires a CorNet-IP SW starting with V5.1.34. The CorNet-IP provides encryption capabilities. Hence its distribution must follow legal requirements which do not allow unrestricted SW distribution via the Internet. The firmware is only provided by Siemens technicians or by official Siemens Partners. Customers with self-care contracts will have access to SW within the SEBA Web portal.

Another option is to register as "Open Developer" at the Technology Partner Website to get XML-enabled phone-SW.

To download SW see SW update optiPoint 410/420 or consult the pdf.png  Administration Manual optiPoint 410-420 family.

Configure applications using web-based management

  • Obtain the IP-address of your phone.
  • Start your web browser and access phone's web-based management by entering https://###.###.###.### (IP-address of your phone).
  • Follow the link: Administration > Enter administrator password (Default: 123456) > Applications.
WBM screenshot Applications
  • Select XML Applications.
WBM screenshot XML Applications
  • Select New program to configure a new application.
WBM screenshot New Program
  • Set the appropriate parameters in the New Program form:


The following comment should be fixed | From Martina.ganzer 16:59, 23 January 2007 (CET) | Show fixme list

Please add example entries, and how can I get these informations when I'm a user.

Parameter Description Comment
Display Name The name of the program as it appears in the program menu on the optiPoint application module. ???
Application Name This is used internally by the application to identify the program running on the telephone ???
Server Address The IP address or domain/host name of the server that provides the application or the XML document.
Server Port number The number of the port that the server uses to provide the application or the XML document. Standard http-port is used.
Program Name on Server The relative path to the servlet or to the first XML page of the application on the server. ???
Use Proxy This specifies whether a Proxy should be used.
  • Yes if you are connected via a Proxy to the internet. This will be mostly the case in enterprises.
  • No if your accessing the internet without a Proxy.
Debug Mode For applications developers only. Don't change.
Debug Program On Server For applications developers only. Don't change.
  • Click Create Program to start generating the program.

For settings please refer to pdf.png  XML developers guide.

XML Tutorial

This XML tutorial is an ideal tool if you start developing XML applications for the optiPoint application module. In conjunction with the pdf.png  XML developers guide it demonstrates how the different XML-objects behave and appear on the screen.

WBM screenshot XML applications > Settings