− | + | == Connect the phone to LAN == | |
# Connect the optiPoint CorNet IP phone to the [[LAN]] (<code>DHCP=on</code> is default). The assumption is that [[DHCP]] is available in your local area network. The phone will reboot. | # Connect the optiPoint CorNet IP phone to the [[LAN]] (<code>DHCP=on</code> is default). The assumption is that [[DHCP]] is available in your local area network. The phone will reboot. | ||
# Depending on the version of the CorNet IP application installed | # Depending on the version of the CorNet IP application installed | ||
− | :* either you may be prompted to enter the Fully qualified subscriber number, then continue with [[#Subscriber number prompted|Subscriber number prompted]] | + | :* either you may be prompted to enter the Fully qualified subscriber number, then continue with [[#Subscriber number is prompted|Subscriber number is prompted]] |
:* or you may '''not''' be prompted to enter the Fully qualified subscriber number, then continue with [[#Subscriber number is not prompted|Subscriber number is not prompted]]. | :* or you may '''not''' be prompted to enter the Fully qualified subscriber number, then continue with [[#Subscriber number is not prompted|Subscriber number is not prompted]]. | ||
+ | |||
+ | == Fully qualified subscriber number == | ||
=== Subscriber number is prompted === | === Subscriber number is prompted === | ||
− | # Enter some digits like [[Image:opk-1.png]] [[Image:opk-2.png]] [[Image:opk-3.png]] ??? | + | # Enter some digits like [[Image:opk-1.png]] [[Image:opk-2.png]] [[Image:opk-3.png]] ???. |
# Confirm <code>Save Changes</code> with the [[Image:opk-ok.png]] key. | # Confirm <code>Save Changes</code> with the [[Image:opk-ok.png]] key. | ||
− | |||
− | |||
Continue with [[#Detect the phone's IP address|Detect the phone's IP address]]. | Continue with [[#Detect the phone's IP address|Detect the phone's IP address]]. | ||
=== Subscriber number is not prompted === | === Subscriber number is not prompted === | ||
− | If you have not been prompted for the subscriber number, the display will show | + | If you have not been prompted for the subscriber number, the display will show <code>Invalide GW Adress</code> or <code>No suscriber number</code>. |
− | |||
− | <code>Invalide GW Adress</code> or <code>No suscriber number</code> | ||
# Press the [[Image:opk-ok.png]] key. | # Press the [[Image:opk-ok.png]] key. | ||
− | # | + | # Continue with [[#Detect the phone's IP address|Detect the phone's IP address]]. |
− | |||
− | |||
− | Continue with [[#Detect the phone's IP address|Detect the phone's IP address]]. | ||
− | + | == Detect the phone's IP address == | |
− | The display | + | The display shows:<br><code>Administration</code><br><code>01=Configuration?</code>. |
− | # | + | # Press the [[Image:opk-ok.png]] key. The display shows:<br><code>Enter admin password</code><br><code>_</code>. |
− | + | # Enter the admin password (default: [[Image:opk-1.png]] [[Image:opk-2.png]] [[Image:opk-3.png]] [[Image:opk-4.png]] [[Image:opk-5.png]] [[Image:opk-6.png]]. The display shows:<br><code>Config:</code><br><code>01=Network?</code>. | |
# Press the [[Image:opk-ok.png]] key and the [[Image:opk-re.png]] key to select <code>02=Terminal IP addr.?</code>. | # Press the [[Image:opk-ok.png]] key and the [[Image:opk-re.png]] key to select <code>02=Terminal IP addr.?</code>. | ||
# You may read the IP address and use this to switch over to the [[WBM]] by using a web browser (Microsoft Internet Explorer recommended). | # You may read the IP address and use this to switch over to the [[WBM]] by using a web browser (Microsoft Internet Explorer recommended). | ||
Line 37: | Line 32: | ||
Continue with [[#Download new firmware|Download new firmware]]. | Continue with [[#Download new firmware|Download new firmware]]. | ||
− | + | == Download new firmware == | |
# In the Web browser's URL row type in <code>http://Phone-IP-Address:8085</code>, e.g. <code>http://192.168.1.2:8085</code>. | # In the Web browser's URL row type in <code>http://Phone-IP-Address:8085</code>, e.g. <code>http://192.168.1.2:8085</code>. | ||
# Enter the Administration menu (default password: ''123456''). | # Enter the Administration menu (default password: ''123456''). | ||
Line 45: | Line 40: | ||
# Continue with [[#Restore factory settings|Restore factory settings]]. | # Continue with [[#Restore factory settings|Restore factory settings]]. | ||
− | + | == Restore factory settings == | |
After successful restart of the application, it is recommended to perform a factory reset. | After successful restart of the application, it is recommended to perform a factory reset. |
Revision as of 16:28, 16 September 2006
This migration procedure is for upgrading an optiPoint 410/420 CorNet IP phone V5.1.2x to SIP V6.0.56 and later.
Contents
Connect the phone to LAN
- Connect the optiPoint CorNet IP phone to the LAN (
DHCP=on
is default). The assumption is that DHCP is available in your local area network. The phone will reboot. - Depending on the version of the CorNet IP application installed
- either you may be prompted to enter the Fully qualified subscriber number, then continue with Subscriber number is prompted
- or you may not be prompted to enter the Fully qualified subscriber number, then continue with Subscriber number is not prompted.
Fully qualified subscriber number
Subscriber number is prompted
Continue with Detect the phone's IP address.
Subscriber number is not prompted
If you have not been prompted for the subscriber number, the display will show Invalide GW Adress
or No suscriber number
.
- Press the key.
- Continue with Detect the phone's IP address.
Detect the phone's IP address
The display shows:Administration
01=Configuration?
.
- Press the key. The display shows:
Enter admin password
_
. - Enter the admin password (default: . The display shows:
Config:
01=Network?
. - Press the key and the key to select
02=Terminal IP addr.?
. - You may read the IP address and use this to switch over to the WBM by using a web browser (Microsoft Internet Explorer recommended).
Continue with Download new firmware.
Download new firmware
- In the Web browser's URL row type in
http://Phone-IP-Address:8085
, e.g.http://192.168.1.2:8085
. - Enter the Administration menu (default password: 123456).
- Select the
Upload/Download
section. - Select
Download application
. - Start a standard FTP server (e.g. 3Com Daemon), and fill out the relevant FTP data, refer to the screenshot below.
- Continue with Restore factory settings.
Restore factory settings
After successful restart of the application, it is recommended to perform a factory reset.
- Select Restore factory setting in the WBM.
- Enter the factory reset password: 124816.
The phone will reboot and start with the updated firmware version.