Difference between revisions of "optiPoint 410/420 CorNet IP (HFA) to SIP migration"
The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.
m (→correction of last change) |
m (General HW compatiblity not only V6.0) |
||
Line 1: | Line 1: | ||
This migration procedure is for upgrading an [[optiPoint 410/420]] CorNet IP phone V5.1.2x to [[SIP]] V6.0.56 and later. | This migration procedure is for upgrading an [[optiPoint 410/420]] CorNet IP phone V5.1.2x to [[SIP]] V6.0.56 and later. | ||
== Precondition == | == Precondition == | ||
− | Please check your hardware revision against the data in the product release note (section "Hardware revisions supported") as not all HW revisions shipped with CorNet IP protocol will support SIP. See also [[SIP V6.0 optiPoint compatibility]]. | + | Please check your hardware revision against the data in the product release note (section "Hardware revisions supported") as not all HW revisions shipped with CorNet IP protocol will support SIP. See also [[SIP V6.0 optiPoint compatibility|optiPoint HW compatibility]]. |
== Connect the phone to LAN == | == Connect the phone to LAN == |
Revision as of 15:22, 19 February 2009
This migration procedure is for upgrading an optiPoint 410/420 CorNet IP phone V5.1.2x to SIP V6.0.56 and later.
Contents
Precondition
Please check your hardware revision against the data in the product release note (section "Hardware revisions supported") as not all HW revisions shipped with CorNet IP protocol will support SIP. See also optiPoint HW compatibility.
Connect the phone to LAN
- Connect the optiPoint CorNet IP phone to the LAN (
DHCP=on
is default). The assumption is that DHCP is available in your local area network. The phone will reboot. - Depending on the version of the CorNet IP application installed
- either you may be prompted to enter the subscriber number, then continue with Subscriber number is prompted
- or you may not be prompted, then continue with Subscriber number is not prompted.
Fully qualified subscriber number
Subscriber number is prompted
- Enter your fully qualified subscriber number.
- Confirm
Save Changes
with the key.
The display shows:Administration
01=Configuration?
Continue with Detect the phone's IP address.
Subscriber number is not prompted
If you have not been prompted for the subscriber number, the display will show Invalide GW Adress
or No subscriber number
.
- Press the key.
The display shows:Administration
01=Configuration?
- Continue with Detect the phone's IP address.
Detect the phone's IP address
- Press the key. The display shows:
Enter admin password
_
- Enter the admin password (default: .
The display shows:Config:
01=Network?
- Press the key and the key to select
02=Terminal IP addr.?
. - You may read the IP address and use this to switch over to the WBM by using a web browser (Microsoft Internet Explorer recommended).
Continue with Download new firmware.
Download new firmware
- In the Web browser's URL row type in
https://Phone-IP-Address
, e.g.https://192.168.1.2
orhttp://Phone-IP-Address:8085
, e.g.http://192.168.1.2:8085
.
- Enter the
Administration
menu (default password: 123456). - Select the
Upload/Download
section. - Select
Download application
. - Start a standard FTP server (e.g. 3Com Daemon), and fill out the relevant FTP data, refer to the screenshot below.
- Continue with Restore factory settings.
Restore factory settings
After successful restart of the application, it is recommended to perform a factory reset.
- Select Restore factory setting in the WBM.
- Enter the factory reset password: 124816.
The phone will reboot and start with the updated firmware version.
See also
- optiPoint 410/420 - the portal page of the telephone family
- optiPoint 410/420 interoperability matrix - comparative table of supported platform versions
- optiPoint 410/420 Release Notes - information about new software features, corrected bugs, known issues
- optiPoint 410/420 V5.1 information - information to optiPoint 410/420 V5.1
- optiPoint 410/420 CorNet IP (HFA) to SIP migration - upgrading CorNet IP V5.1.2x to SIP V6.0.56 and later