− | The '''optiPoint 150 S Release Notes''' describe descending sorted new features, fixed firmware bugs | + | The '''optiPoint 150 S Release Notes''' describe descending sorted new features, fixed firmware bugs and open issues for appropriate firmware versions of the [[optiPoint 150 S]] ({{de}}[[optiPoint 150 S (de)|optiPoint 150 S]]). |
− | == V1.31 == | + | == Software versioning / naming == |
+ | |||
+ | A new software versioning scheme was introduced, it requires that a new versioning name should be adopted for each software product.<br/> | ||
+ | Software product version will be now identified with the string: | ||
+ | |||
+ | ''V''' ''x'''[.'''y'''] ''R'' '''m'''.'''f'''.'''h''' | ||
+ | |||
+ | in which field: | ||
+ | |||
+ | * '''x'''[.'''y'''] denotes the ''Major release'' level | ||
+ | * '''m''' denotes the ''Minor release'' level | ||
+ | * '''f''' denotes the ''Fix release'' level | ||
+ | * '''h''' denotes the ''Hotfix'' level | ||
+ | <br/> | ||
+ | {{Info|This naming convention scheme does '''not''' imply any naming requirements for file / files available.}} | ||
+ | <br/> | ||
+ | More informations on the [[New Software Versioning scheme|New Software Versioning scheme]] wiki page. | ||
+ | |||
+ | == V1 R0.31.0 (V1.31) == | ||
=== What’s New? === | === What’s New? === | ||
Line 33: | Line 51: | ||
− | == V1.28 == | + | == V1 R0.28.0 (V1.28)== |
=== What’s New? === | === What’s New? === | ||
Line 92: | Line 110: | ||
* Symmetric use of UDP ports | * Symmetric use of UDP ports | ||
− | == V1.22 == | + | == V1 R0.22.0 (V1.22) == |
Fixed Bugs and new features: | Fixed Bugs and new features: |
Revision as of 16:48, 23 December 2006
The optiPoint 150 S Release Notes describe descending sorted new features, fixed firmware bugs and open issues for appropriate firmware versions of the optiPoint 150 S ( optiPoint 150 S).
Contents
Software versioning / naming
A new software versioning scheme was introduced, it requires that a new versioning name should be adopted for each software product.
Software product version will be now identified with the string:
V x[.y] R m.f.h
in which field:
- x[.y] denotes the Major release level
- m denotes the Minor release level
- f denotes the Fix release level
- h denotes the Hotfix level
This naming convention scheme does not imply any naming requirements for file / files available. |
More informations on the New Software Versioning scheme wiki page.
V1 R0.31.0 (V1.31)
What’s New?
- Allow alpha numeric phone number, phone name and user ID
- Symmetric UDP Ports
- Support DNS query SRV
- Support DNS TTL
- Support RFC3264 hold for Broadsoft
Fixed Bugs
- Special characters like /, -, @ are now possible to be entered under SIP setup/ SIP settings in the Web based management.
- No Fallback to Inband DTMF
- Number not dialed when going offhook
- Phone plays DTMF digits if called while dialing onhook
- No Registration to SIP Server when DNS name is a canonicle name for an alias
- No automatic callback if a semi-attanded transfer is initiated before Ringing.
- No Ringback tone when doing enquiry
- Semi Attended TRansfer does not work on HiPath 2000
- DNS TTL does not work
- Sylantro ID1.6 Inbound Call when Busy LCD display error
- Sylantro ID3.6 Call-Waiting Interrupted LCD display error
- Call log list always shows the oldest entry at first
- Phone plays DTMF digits if called while dialing.
- Providertest Web.de: No Registration with DNS Name for SIP Server
Known & Open Issues
- The Time Format and Date Format are not changed according to country standard.
- Be able to disable *99 at Sylantro
V1 R0.28.0 (V1.28)
What’s New?
Internal ID | Cluster | New feature | Comment |
---|---|---|---|
N/A | Sylantro | Special call park feature for Sylantro V4.0 | Fixed |
N/A | Sylantro | Special call pick-up feature for Sylantro V4.0 | Fixed |
N/A | Sylantro | Distinctive ringing for Sylantro V4.0 | Fixed |
Fixed Bugs and new features since Version 1.22
- Broadsoft: DHCP Trouble - phone couldn't obtain IP adress via DHCP shortly
- Broadsoft: Should not perform SRV lookup if service domain IPv4 format
- Broadsoft: Failover/failback mechanism
- Broadsoft: Support RFC 3264 Hold for Broadsoft
- IP: New default QoS L3 values (Signalling: AF31 (DSCP 26) and RTP: EF (DSCP 46)
- Admin: Possible to configure Call forwarding at the phone when connected to HP3k, HP4k)Now neither WBM nor local admin can configure CF in this case
- General: Possibiliy to use special characters in SIP-ID like (@, /, %) needed for registration on some of the SIP providers.
- Support of DNS query SRV (DNS_SRV)
- General: alphanumeric SIP_ID’s now possible (e.g. vorname.nachname@provider.com)
- General: Short loud tone when call disconnected (after hook-on for about 200 ms)
- General: Calltransfer not possible after toggle between calls
- General: The "Port field" in the SIP settings should aleady have a default value 5060.
- General: To stay conform with other Siemens phones the default Codec Settings of the OP150S should be changed to "G.711A > G.711U > G.72x"
- General: Not possible to dial after first call was made with Hook on.
- General: Telnet access to optiPoint 150 S
- LAN: phone doesn’t register, if L2 QoS value is set
- LAN: VLAN ID can’t be reset to None
- HiPath 3000: Toggle between calls not possible
- HiPath 3000: Do not disturb is not working
- HiPath 3000: No Ringback tone when calling Upoe or HFA phone @ HP3k (complies now to RFC 3960 sect 3.2)
- HiPath 3000: Busy tone after attended Call transfer
- HiPath 3000: HP3k-HP3k trunking, no payload after transfer
- Phone GUI: Remove possibility to configure Call Forwarding when connected to HiPath 2000, HiPath 3000, HiPath 4000, HiPath 5000
- Telnet port disabled
- Sylantro: Distinctive Ringing (Sylantro) supported
Known & Open Issues
- HiPath 3000: Blind (semi-attended) transfer doesn’t work
- Not possible to dial, after first call was made with Hook on
- Symmetric use of UDP ports
V1 R0.22.0 (V1.22)
Fixed Bugs and new features:
- VLAN ID can't be configured via Phone
- Blind transfer does not work oh H8000
- After factory reset it is still possible to log in as user defined in last saved configuration
- Admin password is not reset after factory reset
- Disable Telnet Access at the optiPoint 150