Views

Difference between revisions of "User talk:Davide.poletto"

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Jump to: navigation, search
m
(Date discussion)
 
(41 intermediate revisions by 2 users not shown)
Line 1: Line 1:
This could be an improvement:
+
This is a DRAFT:
 
 
The new software versioning scheme rules each application software to be named as:
 
 
 
''V'' '''x'''[.'''y'''] ''R'' '''m'''.'''f'''.'''h'''
 
 
 
Where V and R stand for:
 
 
 
* ''V'' = ''Version''
 
** The ''Version'' field is identified by:
 
*** '''x''' = '''Major Release''' as result of ''major feature enhancements'' with M3 status of product.
 
*** '''y''' = as an optional additional numbering.
 
 
 
 
 
* ''R'' = ''Release''
 
** The ''Release'' field is identified by:
 
*** '''m''' = '''Minor Release''' as result of ''minor feature enhancements'' (covers TRs and CRs)
 
*** '''f''' = '''Fix Release''' (FR) as result of a ''collection of solutions to TRs and HFs'' (covers only TRs, no CRs)
 
*** '''h''' = '''Hotfix''' (HF) as result of ''immediate solution to just one TR or only few TRs and to all TRs for Focal and/or Hot accounts'' (a Hotfix comprises all previous HFs, as example those cumulated since the latest FR)
 
 
 
Please note:<br/>
 
FR = Fix Release<br/>
 
TR = Trouble Report<br/>
 
CR = Change Request<br/>
 
HF = Hot Fix<br/>
 
 
 
An example:<br/>
 
 
 
* Product Name: optiPoint 410/420 SIP V6.0
 
* Software Version: V6 R0.62.0
 
<br/>
 
This example shows that the optiPoint 410/420 SIP V6.0 software release version considered:<br/>
 
 
 
* Refers to Version V6 (as Major Release), the additional .0 could be omitted in this case.
 
* Refers to Release R0.62.0
 
** 0 (as Minor Release) <u>so it doesn't introduce any new</u> ''minor feature enhancements''.
 
** 62 (as Fix Release) <u>so it introduces a</u> ''collection of solutions to TRs and HFs''
 
** 0 (as Hotfix) <u>so it doesn't introduce any new</u> ''immediate solution to just one TR or only few TRs''
 
<br/>
 
{{Info|This new software version naming scheme does '''not''' imply any naming requirements for:
 
 
 
* Application files
 
* Loadware files
 
* Firmware files
 
 
 
related to each Software Applications considered.<br/>
 
 
 
This means that, referring to the example above, the software (Application or Firmware) file / files could be named as:<br/>
 
 
 
* opt410adv_SIP_6_0_62.exe containing:
 
** opt410adv_SIP_6_0_62.fli<br/>
 
** opt410adv_SIP_6_0_62.app<br/>
 
 
 
or whatever convenient for its correct usage.<br/>
 
 
 
<u>It's not required nor mandatory that it's named exactly like the software version it's representing</u>.}}
 
 
 
----
 
This is a DRAFT
 
  
 
optiPoint WL2 professional and optiPoint WL2 professional S Surveying Mode overview
 
optiPoint WL2 professional and optiPoint WL2 professional S Surveying Mode overview
Line 68: Line 10:
  
 
* Selectable via the hidden "Service" menu
 
* Selectable via the hidden "Service" menu
* Used to give real-time information of the connected Wireless LAN Access Point ([[AP]])
+
* Used to give real-time information of the connected Wireless LAN Access Point ([[Access Point|AP]])
 
* Available on optiPoint WL2 professional family either in:
 
* Available on optiPoint WL2 professional family either in:
 
** HFA (CorNet IP) software feature set (Since optiPoint WL2 professional V1.0 version 50.002.24.00047)
 
** HFA (CorNet IP) software feature set (Since optiPoint WL2 professional V1.0 version 50.002.24.00047)
Line 89: Line 31:
  
 
=== Submenu List ===
 
=== Submenu List ===
Once into the "Service" menu, the items list is:
+
Once into the "Service" menu, the items are listed in this order:
  
* Network-Scan (''listed as first item'')
+
* Network Scan
 
* SW Release
 
* SW Release
* ...
+
* QS Data
* Surveying Mode (''listed as last item'')
+
* Speechpath test
 +
* Working time
 +
* Contrast
 +
* WPS
 +
* Factory Default
 +
* Clean Up
 +
* Backlight Switch
 +
* Surveying Mode
  
  
Line 160: Line 109:
 
|-
 
|-
 
|}
 
|}
 +
 +
== Interoperability Matrix table TEST ==
 +
 +
Just to incorporate informations about:
 +
 +
* Minimal (supported since...but no technician/field engineer should use this one because since this version "a lot" of development was done, this should be seen as the version since which the device was supported first time)
 +
* Suggested/Recommended (this versione should be used in order to have fixed all the annoying bugs discovered since the Minimal version)
 +
 +
Probably a Tested version label is not so useful (there is the recommended label yet).
 +
 +
Note: Fictionary informations used.
 +
 +
<br/>
 +
 +
{| border="1"
 +
! Release
 +
! HiPath DLS V1.0
 +
! HiPath 2000 V1.0
 +
! Note
 +
|-
 +
| align="left" | [[optiPoint 410/420 S Release Notes#V6 R0.62.0|V6 R0.62.0]]
 +
| align="center" |
 +
{| class="noborder" style="background:#ABCDEF;"
 +
| align="left" | Supported since: R1.27.0
 +
|-
 +
| align="left" | Tested with: R1.27.0<ref name="DLS_V1_R1.27.0">''Note'': tested with HiPath DLS V1.0 software version HI-DLS.10.199.41 released 18/12/2006.</ref>
 +
|-
 +
| align="left" | Recommended: R2.30.0<ref name="DLS_V1_R2.30.0">''Note'': recommended with HiPath DLS V1.0 software version HI-DLS.10.230.20 or newer.</ref>
 +
|}
 +
| align="center" |
 +
{| class="noborder" style="background-color:#ABCDEF;"
 +
| align="left" | Supported: SMR 6 1st CV<ref name="H2k_V1_SMR6_1st_CV">''Note'': supported since HiPath 2000 V1.0 SMR 6 1st CV software version HE620Y.06.475 released on 07/08/2006.</ref>
 +
|-
 +
| align="left" | Tested: R7.0.0<ref name="H2k_V1_R7.0.0">''Note'': tested with HiPath 2000 V1.0 R7.0.0 software version HE620Y.07.554 released on dd/01/2007.</ref>
 +
|-
 +
| align="left" | Recommended: R9.7.0<ref name="H2k_V1_R9.7.0">''Note'': recommended with HiPath 2000 V1.0 R9.7.0 software version HE620Y.09.681 released on 17/05/2007.</ref>
 +
|}
 +
| valign="top" | Test for other general comments
 +
|-
 +
|}
 +
 +
<div class="references-small">
 +
<references/>
 +
</div>
 +
 +
 +
== HiPath MobileConnect TEST ==
 +
 +
HiPath MobileConnect is an enterprise Fixed-Mobile Convergence ([[FMC]]) solution that seamlessly unifies fixed enterprise [[VoIP]], [[VoWLAN]] and cellular mobility
 +
 +
The solution consists of two components:
 +
 +
* HiPath MobileConnect Appliance
 +
Located at the central site, sitting on the wired network between the Wireless LAN and the SIP Communication system it continually monitors and manages mobile user sessions regardless of whether they are on the corporate or public network
 +
 +
* HiPath MobileConnect Client
 +
Software that resides on the dual-mode mobile handset and works with the HiPath MobileConnect Appliance to navigate enterprise-cellular exchange
 +
 +
== Date discussion ==
 +
 +
Hi Davide,
 +
 +
I saw you changed the optiPoint SIP V7 table....
 +
 +
I think we all must think about a clear definition for the table-value "date".
 +
 +
US guys thinks DD/MM/YY, the Europe guys will think MM/DD/YY - often I'm a little bit confused myself... are the two digits at the beginning for month or for day... everytime I have to compare the older release dates ;-)
 +
 +
I think a clear definition like the one specified in ISO 8601 (format  YYYY-MM-DD) will help to prevent misunderstandings.
 +
 +
 +
 +
 +
regards,
 +
Stefan

Latest revision as of 23:31, 10 June 2009

This is a DRAFT:

optiPoint WL2 professional and optiPoint WL2 professional S Surveying Mode overview

... ...

Surveying Mode

This new mode of operation is:

  • Selectable via the hidden "Service" menu
  • Used to give real-time information of the connected Wireless LAN Access Point (AP)
  • Available on optiPoint WL2 professional family either in:
    • HFA (CorNet IP) software feature set (Since optiPoint WL2 professional V1.0 version 50.002.24.00047)
    • SIP software feature set (Since optiPoint WL2 professional S V1.0 version 70.042.90)
  • Used to enhance the serviceability of the WLAN workpoints
  • Used to perform WLAN site surveys and deployments.

Service Menu

optiPoint WL2 professional and optiPoint WL2 professional S have an hidden "Service" menu

Accessing

Steps to access the hidden "Service" menu on the workpoint:

  • Turn off the optiPoint WL2 professional
  • Press simultaneously and hold dial pad buttons 1-4-7 and On Hook key (Power button) at the same time
  • The hourglass icon appears in the phone display
  • Keep them pressed, releasing the Power button in the while, until Speakerphone's LED and the MWI's LED are activated and flashing red (Blinking)
  • The optiPoint WL2 professional powers up showing "Service" on the display
  • Enter code 76200 to access displayed "Service" menu

Submenu List

Once into the "Service" menu, the items are listed in this order:

  • Network Scan
  • SW Release
  • QS Data
  • Speechpath test
  • Working time
  • Contrast
  • WPS
  • Factory Default
  • Clean Up
  • Backlight Switch
  • Surveying Mode



Feature EVM (Entry Voice Mail) IVM (Integrated Voice Mail) Note
Port (Channels) 2 8 / 24 8 for ..., 24 for ...
Total storage capacity 2 h 100 h
Mailboxes up to 24 up to 500
Mailboxes greeting messages up to 2 up to 4
Mailboxes greeting messages length up to 1 min up to 3 min
Auto Attendant (AA) mailboxes up to 4 up to 100
Auto Attendant (AA) mailboxes greeting messages up to 2 up to 4
Auto Attendant (AA) mailboxes greeting messages length up to 2 min up to 8 min
Information mailboxes up to 100
Information mailboxes greeting messages up to 4
Information mailboxes greeting messages length up to 20 min

Interoperability Matrix table TEST

Just to incorporate informations about:

  • Minimal (supported since...but no technician/field engineer should use this one because since this version "a lot" of development was done, this should be seen as the version since which the device was supported first time)
  • Suggested/Recommended (this versione should be used in order to have fixed all the annoying bugs discovered since the Minimal version)

Probably a Tested version label is not so useful (there is the recommended label yet).

Note: Fictionary informations used.


Release HiPath DLS V1.0 HiPath 2000 V1.0 Note
V6 R0.62.0
Supported since: R1.27.0
Tested with: R1.27.0[1]
Recommended: R2.30.0[2]
Supported: SMR 6 1st CV[3]
Tested: R7.0.0[4]
Recommended: R9.7.0[5]
Test for other general comments
  1. Note: tested with HiPath DLS V1.0 software version HI-DLS.10.199.41 released 18/12/2006.
  2. Note: recommended with HiPath DLS V1.0 software version HI-DLS.10.230.20 or newer.
  3. Note: supported since HiPath 2000 V1.0 SMR 6 1st CV software version HE620Y.06.475 released on 07/08/2006.
  4. Note: tested with HiPath 2000 V1.0 R7.0.0 software version HE620Y.07.554 released on dd/01/2007.
  5. Note: recommended with HiPath 2000 V1.0 R9.7.0 software version HE620Y.09.681 released on 17/05/2007.


HiPath MobileConnect TEST

HiPath MobileConnect is an enterprise Fixed-Mobile Convergence (FMC) solution that seamlessly unifies fixed enterprise VoIP, VoWLAN and cellular mobility

The solution consists of two components:

  • HiPath MobileConnect Appliance

Located at the central site, sitting on the wired network between the Wireless LAN and the SIP Communication system it continually monitors and manages mobile user sessions regardless of whether they are on the corporate or public network

  • HiPath MobileConnect Client

Software that resides on the dual-mode mobile handset and works with the HiPath MobileConnect Appliance to navigate enterprise-cellular exchange

Date discussion

Hi Davide,

I saw you changed the optiPoint SIP V7 table....

I think we all must think about a clear definition for the table-value "date".

US guys thinks DD/MM/YY, the Europe guys will think MM/DD/YY - often I'm a little bit confused myself... are the two digits at the beginning for month or for day... everytime I have to compare the older release dates ;-)

I think a clear definition like the one specified in ISO 8601 (format YYYY-MM-DD) will help to prevent misunderstandings.



regards, Stefan