Difference between revisions of "User talk:Davide.poletto"
The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.
m (→Test) |
(Date discussion) |
||
(25 intermediate revisions by 2 users not shown) | |||
Line 10: | Line 10: | ||
* Selectable via the hidden "Service" menu | * Selectable via the hidden "Service" menu | ||
− | * Used to give real-time information of the connected Wireless LAN Access Point ([[AP]]) | + | * Used to give real-time information of the connected Wireless LAN Access Point ([[Access Point|AP]]) |
* Available on optiPoint WL2 professional family either in: | * Available on optiPoint WL2 professional family either in: | ||
** HFA (CorNet IP) software feature set (Since optiPoint WL2 professional V1.0 version 50.002.24.00047) | ** HFA (CorNet IP) software feature set (Since optiPoint WL2 professional V1.0 version 50.002.24.00047) | ||
Line 31: | Line 31: | ||
=== Submenu List === | === Submenu List === | ||
− | Once into the "Service" menu, the items | + | Once into the "Service" menu, the items are listed in this order: |
− | * Network | + | * Network Scan |
* SW Release | * SW Release | ||
− | * | + | * QS Data |
− | * Surveying Mode | + | * Speechpath test |
+ | * Working time | ||
+ | * Contrast | ||
+ | * WPS | ||
+ | * Factory Default | ||
+ | * Clean Up | ||
+ | * Backlight Switch | ||
+ | * Surveying Mode | ||
Line 103: | Line 110: | ||
|} | |} | ||
− | == | + | == Interoperability Matrix table TEST == |
− | + | Just to incorporate informations about: | |
− | {| | + | * Minimal (supported since...but no technician/field engineer should use this one because since this version "a lot" of development was done, this should be seen as the version since which the device was supported first time) |
+ | * Suggested/Recommended (this versione should be used in order to have fixed all the annoying bugs discovered since the Minimal version) | ||
+ | |||
+ | Probably a Tested version label is not so useful (there is the recommended label yet). | ||
+ | |||
+ | Note: Fictionary informations used. | ||
+ | |||
+ | <br/> | ||
+ | |||
+ | {| border="1" | ||
! Release | ! Release | ||
! HiPath DLS V1.0 | ! HiPath DLS V1.0 | ||
− | ! | + | ! HiPath 2000 V1.0 |
− | ! [[ | + | ! Note |
− | + | |- | |
− | + | | align="left" | [[optiPoint 410/420 S Release Notes#V6 R0.62.0|V6 R0.62.0]] | |
− | + | | align="center" | | |
− | + | {| class="noborder" style="background:#ABCDEF;" | |
− | + | | align="left" | Supported since: R1.27.0 | |
− | + | |- | |
− | + | | align="left" | Tested with: R1.27.0<ref name="DLS_V1_R1.27.0">''Note'': tested with HiPath DLS V1.0 software version HI-DLS.10.199.41 released 18/12/2006.</ref> | |
− | |||
− | |||
|- | |- | ||
− | | | + | | align="left" | Recommended: R2.30.0<ref name="DLS_V1_R2.30.0">''Note'': recommended with HiPath DLS V1.0 software version HI-DLS.10.230.20 or newer.</ref> |
− | + | |} | |
− | | SMR 6 1st CV<ref name="H2k_V1_SMR6_1st_CV">'''HiPath 2000 V1.0 | + | | align="center" | |
− | | | + | {| class="noborder" style="background-color:#ABCDEF;" |
− | | | + | | align="left" | Supported: SMR 6 1st CV<ref name="H2k_V1_SMR6_1st_CV">''Note'': supported since HiPath 2000 V1.0 SMR 6 1st CV software version HE620Y.06.475 released on 07/08/2006.</ref> |
− | | | + | |- |
− | + | | align="left" | Tested: R7.0.0<ref name="H2k_V1_R7.0.0">''Note'': tested with HiPath 2000 V1.0 R7.0.0 software version HE620Y.07.554 released on dd/01/2007.</ref> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | align="left" | Recommended: R9.7.0<ref name="H2k_V1_R9.7.0">''Note'': recommended with HiPath 2000 V1.0 R9.7.0 software version HE620Y.09.681 released on 17/05/2007.</ref> |
− | + | |} | |
− | + | | valign="top" | Test for other general comments | |
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | |||
|- | |- | ||
|} | |} | ||
− | <references /> | + | <div class="references-small"> |
+ | <references/> | ||
+ | </div> | ||
+ | |||
+ | |||
+ | == HiPath MobileConnect TEST == | ||
+ | |||
+ | HiPath MobileConnect is an enterprise Fixed-Mobile Convergence ([[FMC]]) solution that seamlessly unifies fixed enterprise [[VoIP]], [[VoWLAN]] and cellular mobility | ||
+ | |||
+ | The solution consists of two components: | ||
+ | |||
+ | * HiPath MobileConnect Appliance | ||
+ | Located at the central site, sitting on the wired network between the Wireless LAN and the SIP Communication system it continually monitors and manages mobile user sessions regardless of whether they are on the corporate or public network | ||
+ | |||
+ | * HiPath MobileConnect Client | ||
+ | Software that resides on the dual-mode mobile handset and works with the HiPath MobileConnect Appliance to navigate enterprise-cellular exchange | ||
+ | |||
+ | == Date discussion == | ||
+ | |||
+ | Hi Davide, | ||
+ | |||
+ | I saw you changed the optiPoint SIP V7 table.... | ||
+ | |||
+ | I think we all must think about a clear definition for the table-value "date". | ||
+ | |||
+ | US guys thinks DD/MM/YY, the Europe guys will think MM/DD/YY - often I'm a little bit confused myself... are the two digits at the beginning for month or for day... everytime I have to compare the older release dates ;-) | ||
+ | |||
+ | I think a clear definition like the one specified in ISO 8601 (format YYYY-MM-DD) will help to prevent misunderstandings. | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | regards, | ||
+ | Stefan |
Latest revision as of 23:31, 10 June 2009
This is a DRAFT:
optiPoint WL2 professional and optiPoint WL2 professional S Surveying Mode overview
... ...
Contents
Surveying Mode
This new mode of operation is:
- Selectable via the hidden "Service" menu
- Used to give real-time information of the connected Wireless LAN Access Point (AP)
- Available on optiPoint WL2 professional family either in:
- HFA (CorNet IP) software feature set (Since optiPoint WL2 professional V1.0 version 50.002.24.00047)
- SIP software feature set (Since optiPoint WL2 professional S V1.0 version 70.042.90)
- Used to enhance the serviceability of the WLAN workpoints
- Used to perform WLAN site surveys and deployments.
Service Menu
optiPoint WL2 professional and optiPoint WL2 professional S have an hidden "Service" menu
Accessing
Steps to access the hidden "Service" menu on the workpoint:
- Turn off the optiPoint WL2 professional
- Press simultaneously and hold dial pad buttons 1-4-7 and On Hook key (Power button) at the same time
- The hourglass icon appears in the phone display
- Keep them pressed, releasing the Power button in the while, until Speakerphone's LED and the MWI's LED are activated and flashing red (Blinking)
- The optiPoint WL2 professional powers up showing "Service" on the display
- Enter code 76200 to access displayed "Service" menu
Once into the "Service" menu, the items are listed in this order:
- Network Scan
- SW Release
- QS Data
- Speechpath test
- Working time
- Contrast
- WPS
- Factory Default
- Clean Up
- Backlight Switch
- Surveying Mode
Feature | EVM (Entry Voice Mail) | IVM (Integrated Voice Mail) | Note |
---|---|---|---|
Port (Channels) | 2 | 8 / 24 | 8 for ..., 24 for ... |
Total storage capacity | 2 h | 100 h | |
Mailboxes | up to 24 | up to 500 | |
Mailboxes greeting messages | up to 2 | up to 4 | |
Mailboxes greeting messages length | up to 1 min | up to 3 min | |
Auto Attendant (AA) mailboxes | up to 4 | up to 100 | |
Auto Attendant (AA) mailboxes greeting messages | up to 2 | up to 4 | |
Auto Attendant (AA) mailboxes greeting messages length | up to 2 min | up to 8 min | |
Information mailboxes | up to 100 | ||
Information mailboxes greeting messages | up to 4 | ||
Information mailboxes greeting messages length | up to 20 min |
Interoperability Matrix table TEST
Just to incorporate informations about:
- Minimal (supported since...but no technician/field engineer should use this one because since this version "a lot" of development was done, this should be seen as the version since which the device was supported first time)
- Suggested/Recommended (this versione should be used in order to have fixed all the annoying bugs discovered since the Minimal version)
Probably a Tested version label is not so useful (there is the recommended label yet).
Note: Fictionary informations used.
Release | HiPath DLS V1.0 | HiPath 2000 V1.0 | Note | ||||||
---|---|---|---|---|---|---|---|---|---|
V6 R0.62.0 |
|
|
Test for other general comments |
- ↑ Note: tested with HiPath DLS V1.0 software version HI-DLS.10.199.41 released 18/12/2006.
- ↑ Note: recommended with HiPath DLS V1.0 software version HI-DLS.10.230.20 or newer.
- ↑ Note: supported since HiPath 2000 V1.0 SMR 6 1st CV software version HE620Y.06.475 released on 07/08/2006.
- ↑ Note: tested with HiPath 2000 V1.0 R7.0.0 software version HE620Y.07.554 released on dd/01/2007.
- ↑ Note: recommended with HiPath 2000 V1.0 R9.7.0 software version HE620Y.09.681 released on 17/05/2007.
HiPath MobileConnect TEST
HiPath MobileConnect is an enterprise Fixed-Mobile Convergence (FMC) solution that seamlessly unifies fixed enterprise VoIP, VoWLAN and cellular mobility
The solution consists of two components:
- HiPath MobileConnect Appliance
Located at the central site, sitting on the wired network between the Wireless LAN and the SIP Communication system it continually monitors and manages mobile user sessions regardless of whether they are on the corporate or public network
- HiPath MobileConnect Client
Software that resides on the dual-mode mobile handset and works with the HiPath MobileConnect Appliance to navigate enterprise-cellular exchange
Date discussion
Hi Davide,
I saw you changed the optiPoint SIP V7 table....
I think we all must think about a clear definition for the table-value "date".
US guys thinks DD/MM/YY, the Europe guys will think MM/DD/YY - often I'm a little bit confused myself... are the two digits at the beginning for month or for day... everytime I have to compare the older release dates ;-)
I think a clear definition like the one specified in ISO 8601 (format YYYY-MM-DD) will help to prevent misunderstandings.
regards,
Stefan