Difference between revisions of "optiPoint 410/420 Release Notes"
The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.
m (→Fixed Bugs) |
m (→V5 R1.34.0) |
||
Line 98: | Line 98: | ||
== V5 R1.34.0== | == V5 R1.34.0== | ||
Back to [[optiPoint 410/420|optiPoint 410/420 productpage]]. | Back to [[optiPoint 410/420|optiPoint 410/420 productpage]]. | ||
+ | |||
+ | Pls consider ''Readme'' tag for updates in corresponding documents. | ||
+ | * {{File-DL|Administration Manual optiPoint 410-420 family|pdf}} | ||
=== What’s New? === | === What’s New? === |
Revision as of 15:07, 27 November 2006
Overview
optiPoint V5.1 was released to market in March 2005.
Major enhancement is the introduction of confidentiality (SRTP Payload encryption) in this release.
See also general information about optiPoint 410/420 V5.1
V5 R1.35.0
Back to optiPoint 410/420 productpage.
What’s New?
No new features!
Fixed Bugs
ID | MR ID | Summary |
---|---|---|
G85350 | DLS10: No bulk SW deployment possible with V5 R1.34.0 | |
NA02424549 | G84096 | Reboot of phone when using Park feature |
NA02376575 | G82156 | FA: optiPoint Application Module doesn't work |
G86288 | H.235 Security: new default for security time window | |
NA01978927 | G75435 | Sporadically no display message after touching the phone |
NA01951058<br\>NA01777953 | G61064 | optiPoint 420 advance+Keymodule HFA V5.1.11: Sporadically keymodule goes out of service |
NA02391266 | G84350 | self-labeling-key Module goes out of Service |
G84414 | Memory leak when using H.235 security | |
G85757 | No DeploymentTool support with V5 R1.33.0 and V5 R1.34.0 |
Known & Open Issues
ID | MR ID | Summary | Workaround |
---|---|---|---|
NA02123627 | G73190 | V5.1.28 with APM V1.02 export crash | N/A |
NA02032712 | G71308 | V5.1.25: Time Settings | N/A |
NA02034671 | G71503 | PCUserClient410.exe doesn't work | N/A |
NA01295901 | G37196 | No system menu shown via CTI | N/A |
NA02121417 | Sporadically no connection to headset | N/A | |
NA02278982 | G79492 | Wrong QDC Values for every 1 hour report | N/A |
V5 R1.34.0
Back to optiPoint 410/420 productpage.
Pls consider Readme tag for updates in corresponding documents.
What’s New?
ID | MR ID | Summary |
---|---|---|
RQ00020844 | XML / AGP Interface on optiPoint IP Phones Introduction of an "Application Generic Platform (AGP)" offers now the possibility to run server based XML-applications on an application module. The phone communicates with the server using XML. |
Fixed Bugs
ID | MR ID | Summary |
---|---|---|
G84107 | AGP: Configurable Backlight | |
G79726 | AGP: Virtual keyboard problems following app pause. | |
G82097 | AGP platform not updated on applicaiton download | |
G79728 | AGP: Carraige return on textbox overides text constraint |
Known & Open Issues
ID | MR ID | Summary | Workaround |
---|---|---|---|
NA02123627 | G73190 | 5.1.28 with APM V1.02 export chrash | N/A |
NA02032712 | G71308 | V5.1.25: Time Settings | N/A |
NA02034671 | G71503 | PCUserClient410.exe doesn't work | N/A |
NA01295901 | G37196 | No systemmenue shown via cti | N/A |
NA01951058 | G61064 | Op420adv+keymodule HFA V.5.1.11 | N/A |
NA02121417 | Sporadically no connection to headset | N/A | |
NA02278982 | G79492 | Wrong QDC Values for every 1 hour report | N/A |
NA02391266 | G84350 | Spoardically SLK Module goes out of service | N/A |
NA01978927 | G75435 | Sporadically no display message after touching the phone | N/A |
NA01777953 | G61064 | Sporadically keymodule goes out of service | N/A |
V5 R1.33.0
Back to optiPoint 410/420 productpage.
What’s New?
ID | MR ID | Summary |
---|---|---|
RQ00018841 | G73191 | Remote Netboot Upgrade This CR enables the Netboot firmware to be upgraded using the standard SW-update methodologies (WBM or DLS). |
RQ00021052 | G75897 | New Software Versioning scheme to be implemented The version string format has been changed from e.g. 5.1.33 to V5R1.33.0. This modification causes a modified information being displayed during the phone boot sequence. |
G82942 | Introduce Configurable Min. Jitter Buffer Target Introduction of .... | |
RQ00021139 | Display of Netboot SW Version in DLS |
Fixed Bugs
ID | MR ID | Summary |
---|---|---|
NA02391321 | G82330 | Optipoint restart after pickup call |
G78331 | DLS10: Missing Item informationof NETBOOT Version | |
G82254 | Half-way Payload conn. about PPP at 30s Calling | |
G74863 | payload lost after nmap port scan of H.245 port |
Known & Open Issues
ID | MR ID | Summary | Workaround |
---|---|---|---|
NA02123627 | G73190 | 5.1.28 with APM V1.02 export chrash | N/A |
NA02032712 | G71308 | V5.1.25: Time Settings | N/A |
NA02034671 | G71503 | PCUserClient410.exe doesn't work | N/A |
NA01295901 | G37196 | No systemmenue shown via cti | N/A |
NA01951058 | G61064 | Op420adv+keymodule HFA V.5.1.11 | N/A |
NA02121417 | Spoardically no connection to headset | N/A | |
NA02278982 | G79492 | Wrong QDC Values for every 1 hour report | N/A |
V5.1.32
Back to optiPoint 410/420 productpage.
What’s New?
No new features!
Fixed Bugs
ID | MR ID | Summary |
---|---|---|
G74951 | Reboot when connection established from op600 | |
NA01914496 | G32375 | WBM not available |
G69356 | DLS10: SRSR: different GW-ID not possible for op410/420 | |
NA02136997 | G76449 | Op410: V5.1.26: Sporadically optiPoint play no Audio |
G76443 | oP410 IP phone one way transmission on external calls | |
G76632 | IP Phone 1-way xmission on internal calls | |
NA02088884 | G46610 | Acoustic adapter interrupt connection |
G78208 | INCA-IP V1.4 Errata - DSP Memory Error workaround | |
G75531 | LDAP Client Improvements | |
G77965 | Web diagnostic logging page not accessible |
Known & Open Issues
ID | MR ID | Summary | Workaround |
---|---|---|---|
NA02123627 | G73190 | 5.1.28 with APM V1.02 export chrash | N/A |
NA01914496 | G32375 | WBM not available | N/A |
NA02032712 | G71308 | V5.1.25: Time Settings | N/A |
NA02034671 | G71503 | PCUserClient410.exe doesn't work | N/A |
NA02054162 | G19681 | SEC: WBM blocked after nmap port scan | N/A |
NA01295901 | G37196 | No systemmenue shown via cti | N/A |
NA01951058 | G61064 | Op420adv+keymodule HFA V.5.1.11 | N/A |
V5.1.31
Back to optiPoint 410/420 productpage.
What’s New?
ID | MR ID | Summary |
---|---|---|
RQ00019055 | G58170 | RFC2833 DTMF on HFA Depending on endpoint capabilities, the endpoint can now send DTMF tones as packets encoded according to RFC 2833 standard. |
RQ00015019 | G34093 | Personal Password for Callbridge-IP The Callbridge-IP connection is now authenticated using the "User" password as established in the user section of the WBM. |
NA01680321 | G63158 | USA: Limitation on number of VoIP calls The number of internal call records that can be maintained has been increased from 3 to 4. This change is relevant for H2km H3k, H5k only. |
Fixed Bugs
ID | MR ID | Summary |
---|---|---|
NA01089158 | G65693 | Very low volume at OP4x0 with loud background noice |
NA02035910 | G19681 | SEC: WBM blocked after nmap port scan |
G66324 | RQ00019050: No AU_SEND_DTMF_ACK from IP phones | |
G42604 | Mobility - 3k mobile session not restored after power fail | |
G44252 | DLS10: LDAP default values sent from phone (eco/entry) | |
G66521 | IP Mobility Supervisor not working when H235 enabled | |
G73906 | Config Service needs re-introducing for old style Dep. tool |
Known & Open Issues
ID | MR ID | Summary | Workaround |
---|---|---|---|
NA02123627 | G73190 | 5.1.28 with APM V1.02 export chrash | N/A |
NA02032712 | G71308 | V5.1.25: Time Settings | N/A |
NA02034671 | G71503 | PCUserClient410.exe doesn't work | N/A |
NA01295901 | G37196 | No systemmenue shown via cti | N/A |
NA01951058 | G61064 | Op420adv+keymodule HFA V.5.1.11 | N/A |
V5.1.30
Back to optiPoint 410/420 productpage.
What’s New?
No new features!
Fixed Bugs
ID | MR ID | Summary |
---|---|---|
NA02044848 | G70245 | Phone Reboot initiated via http contact |
G54369 | Starting Java Midlet after ENB start is impossible. | |
G56818 | 2 pty IP Phone HFA -long duration call- RTP Stops | |
G64294 | 802.1x: no indication of 802.1x re-authentication failure | |
G65716 | op410 Entry - no indication of 802.1x status | |
G67158 | EAP Respons contains no phone certificate | |
G67178 | op410 SiemensTLS hangs if negotiation will not finished | |
G69248 | op410 sends wrong user name in EAP Identity Response to IAS | |
G52307 | 802.1x: loss of speech during 802.1x re-authentication | |
G69070 | CR 14332: No dialtone after SRSR to STBY if H235 aktivated | |
G64478 | DLS10: Dialing properties, Ext. acc code: leading 0 cut | |
G31620 | DLS10: negative timezone offset values from DLS not displ. | |
G57012 | DLS10: neg. Timezone offset not applied by phone | |
NA01912039 | G65705 | DLS10: NA01912039, P&P with E164 spor. NOK |
G67414 | DLS10: Wrong behavior after faulty filetransfer | |
G67575 | optiPoint 410/420 logging to File doesn't work in 5.1.25 | |
NA01837680 | G63033 | Display with netboot 3.06 disorted |
G68883 | USB keyboard: German keys don't invoke ENB | |
G53500 | No "Done" Button after Online Help and hits Virtual keyboard | |
G54486 | No german text for restart request when running Java applet | |
G59426 | Default fast-start offer not optimal for HiPath 3K | |
G67418 | SRSR failure to switch back automatically | |
NA01807670 | G61591 | Op420adv HFA V5.1.18 no Speech |
G45631 | close Java midlet file with "Enter" Key not possible | |
G72708 | V5.1.29: Phone can't login after Mobile Forced Logoff | |
NA01995346 | G69856 | OP4xx in "Logging On" after system shutdown |
G71338 | After hold, HFA has one way speech path |
Known & Open Issues
ID | MR ID | Summary | Workaround |
---|---|---|---|
NA02123627 | G73190 | 5.1.28 with APM V1.02 export chrash | N/A |
NA01914496 | G32375 | WBM not available | N/A |
NA02032712 | G71308 | V5.1.25: Time Settings | N/A |
NA02034671 | G71503 | PCUserClient410.exe doesn't work | N/A |
NA02054162 | G19681 | SEC: WBM blocked after nmap port scan | N/A |
NA01295901 | G37196 | No systemmenue shown via cti | N/A |
NA01951058 | G61064 | Op420adv+keymodule HFA V.5.1.11 | N/A |