Views

Difference between revisions of "Talk:HiPath 500"

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Jump to: navigation, search
Line 14: Line 14:
  
 
Perhaps someone can point me to the documentation, and when I have the answers, perhaps I could contribute a HowTo. --[[User:Tonyf|Tonyf]] 17:12, 7 August 2007 (CEST)
 
Perhaps someone can point me to the documentation, and when I have the answers, perhaps I could contribute a HowTo. --[[User:Tonyf|Tonyf]] 17:12, 7 August 2007 (CEST)
 +
 +
----
 +
: Getting somewhere
 +
 +
: Used *95 on optipoint phone to get to System Admin and entered user and password OK.
 +
: Then 2239 - IP access and managed to set the various IP parameters (* ends up as . in IP addresses)
 +
: I can now ping its address and get a response.
 +
: Run 3000 Manager C and click the "Transfer" icon, sesect 'IP HiPath' and enter the IP address.
 +
: Then click 'System -> PC' button, wait, and get "User has no rights to perform this action" so I'm back to 'Try anything' mode. --[[User:Tonyf|Tonyf]] 19:23, 7 August 2007 (CEST)

Revision as of 17:23, 7 August 2007

Hallo Fotos von der 520 & 540 sollten doch auch noch irgendwo auf zu treiben sein oder? --SCCSSF 12:45, 5 December 2006 (CET)


Kommt noch - Geduld, Geduld ... --Horemu 17:34, 5 December 2006 (CET)

HiPath 3000 Manager C to HiPath 540

I'm trying to make a network connection between the Manager software on my PC and a new HiPath 540 PBX box.

I am unable to find any documentation on this. The documents I have which came on the CD and with the software installed from it indicate the need for MAC address (which I have) and IP address (which I don't have) and suggest that these may be found from an optipoint (economy?) station attached to the 540. Searches of the documentation provide no further information.

Perhaps someone can point me to the documentation, and when I have the answers, perhaps I could contribute a HowTo. --Tonyf 17:12, 7 August 2007 (CEST)


Getting somewhere
Used *95 on optipoint phone to get to System Admin and entered user and password OK.
Then 2239 - IP access and managed to set the various IP parameters (* ends up as . in IP addresses)
I can now ping its address and get a response.
Run 3000 Manager C and click the "Transfer" icon, sesect 'IP HiPath' and enter the IP address.
Then click 'System -> PC' button, wait, and get "User has no rights to perform this action" so I'm back to 'Try anything' mode. --Tonyf 19:23, 7 August 2007 (CEST)