Views

optiPoint 410/420 S factory reset

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Jump to: navigation, search

The reset to factory defaults at optiPoint 410/420 S phones can be done by Web-based management and local phone procedure.

optiPoint 410/420 S display phones

By Web-based management

Connect to the WBM and login as administrator. Select the item "Reset factory setting" and enter the reset PW 124816.

Note: Since factory settings may differ to the settings used for connecting to the WBM before, you may need to check IP address and L2/L3 settings before you can continue working with the WBM.

Select the item "Reset factory setting"

By local phone procedure

Ensure that call control is on the phone, not the DSM ???.

  • Disconnect phone from LAN (only required for netboot < V2.01, PoE devices temporarily need external power supply).
  • Lift handset.
  • Type in reset code opk-minus.png opk-plus.png opk-ast.png opk-3.png.
  • Type in reset password opk-1.png opk-2.png opk-4.png opk-8.png opk-1.png opk-6.png.
  • Replace handset.
  • If required, re-connect phone to LAN.

optiPoint 410 entry S

By Web-based management

(TBD)

By local phone procedure

  • Disconnect phone from LAN (except PoE).
  • Press keys simultaneously opk-3.png opk-8.png opk-9.png.
  • Press the key opk-ast.png.
  • Type in reset password opk-1.png opk-2.png opk-4.png opk-8.png opk-1.png opk-6.png.
  • Press the key opk-rau.png.
  • Connect phone to LAN (except PoE).