Views

Difference between revisions of "optiPoint 150 S Release Notes"

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Jump to: navigation, search
Line 132: Line 132:
 
* Telnet port disabled
 
* Telnet port disabled
 
* Distinctive Ringing (Sylantro) supported
 
* Distinctive Ringing (Sylantro) supported
 +
 +
 +
 +
== V1.22 ==
 +
 +
{| {{DefaultTable}}
 +
! Internal ID
 +
! Cluster
 +
! New feature
 +
! Comment
 +
|-
 +
| 323
 +
|
 +
| VLAN ID can't be configured via Phone
 +
| Fixed
 +
|-
 +
| 356
 +
|
 +
| Blind transfer does not work oh H8000
 +
| Fixed
 +
|-
 +
| 358
 +
|
 +
| After factory reset it is still possible to log in as user defined in last saved configuration
 +
| Fixed
 +
|-
 +
| 361
 +
|
 +
| Admin password is not reset after factory reset
 +
| Fixed
 +
|-
 +
| 380
 +
|
 +
| Disable Telnet Access at the optiPoint 150
 +
| Fixed
 +
|-
 +
|}

Revision as of 07:53, 28 September 2006

The optiPoint 150 S Release Notes describe descending sorted new features, fixed firmware bugs und open issues for appropriate firmware versions of the optiPoint 150 S (Deutschland optiPoint 150 S).

V1.28

What’s New?

Internal ID Cluster New feature Comment
N/A Sylantro Special call park feature for Sylantro V4.0 Fixed
N/A Sylantro Special call pick-up feature for Sylantro V4.0 Fixed
N/A Sylantro Distinctive ringing for Sylantro V4.0 Fixed

V1.27

What’s New?

Fixing of faults related to the Broadsoft and Sylantro platform

Fixed Bugs

Internal ID Cluster Problem Comment
3692 Broadsoft DHCP Trouble - phone couldn't obtain IP adress via DHCP shortly Fixed
3693 Broadsoft Should not perform SRV lookup if service domain IPv4 format Fixed
3694 Broadsoft Failover/failback mechanism Fixed

V1.26

What’s New?

Internal ID Cluster New feature Comment
398 IP New default QoS L3 values Signalling: AF31 (DSCP 26) and RTP: EF (DSCP 46)

Fixed Bugs

Internal ID Cluster Problem Comment
400 HP3k No Ringback tone when calling Upoe or HFA phone @ HP3k complies now to RFC 3960 sect 3.2
392 Admin Possible to configure Call forwarding at the phone when connected to HP3k, HP4k) Now neither WBM nor local admin can configure CF in this case (correct!)
N/A IP Phone is sending out ARP requests for IP: 192.1.1.49 But this IP is NOWHERE configured in the phone.

V1.25

Fixed Bugs

  • General: Possibiliy to use special characters in SIP-ID like (@, /, %) needed for registration on some of the SIP providers.

V1.24

What’s New?

  • Support of DNS query SRV (DNS_SRV)
  • Support DNS TTL
  • Support RFC 3264 Hold for Broadsoft

Fixed Bugs

  • General: alphanumeric SIP_ID’s now possible (e.g. vorname.nachname@provider.com)
  • General: Loud tone when call disconnected
  • General: Calltransfer not possible after toggle between calls
  • LAN: phone doesn’t register, if L2 QoS value is set
  • LAN: VLAN ID can’t be reset to None
  • HiPath 3000: Toggle between calls not possible
  • HiPath 3000: Busy tone after attended Call transfer
  • HiPath 3000: HP3k-HP3k trunking, no payload after transfer
  • Phone GUI: Remove possibility to configure Call Forwarding when connected to HiPath 2000, HiPath 3000, HiPath 4000, HiPath 5000

Known & Open Issues

  • HiPath 3000: Blind (semi-attended) transfer doesn’t work
  • Not possible to dial, after first call was made with Hook on
  • Symmetric use of UDP ports (planned for V1.25)

V1.23

What’s New?

  • Telnet port disabled
  • Distinctive Ringing (Sylantro) supported


V1.22

Internal ID Cluster New feature Comment
323 VLAN ID can't be configured via Phone Fixed
356 Blind transfer does not work oh H8000 Fixed
358 After factory reset it is still possible to log in as user defined in last saved configuration Fixed
361 Admin password is not reset after factory reset Fixed
380 Disable Telnet Access at the optiPoint 150 Fixed