Views

hipath cordless

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Revision as of 18:41, 28 November 2008 by Toppmoeller (talk | contribs) (hipath cordless v3.0)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Hallo, i'm on hipath 4000 v4.2_1 and hotfix 42 , on the pbx there's an Slc24 q2193-x200 with the last loadware pzdslc25 cv373 the following error occoured: with res-dssuen,1-2-109-0; the system deactive the base station bs4 on circuit 0 so with dis-slcb:bssc,data,2,109,0; byte 12 &13 are 02 FF ad insert the following comment:

RES-DSSU:PEN,1-2-109-0; H500: AMO DSSU STARTED H33: PEN 1-2-109-0 WAS ALREADY DEACTIVATED H22: BASE STATION CAN BE LOADED ONLY BY MEANS OF EXEC-DSSU:1,2,109;

but with the command exec-dssu:1,2,109; nothing happened i have to use act-dssu:aul,pen,1-2-109-0; the bs4 will be loaded correctly

if i use the command line step by step this is the scenario:

<ex-dssu: LTG = 1 LTU = 2 SLOT = 109 CIR = 0 M34: VALUE NOT WITHIN ADMISSIBLE RANGE CIR = ?? CIR : CIRCUIT NUMBER CHARACTERISTIC : OPTIONAL MINIMUM : 1 VALUES MAXIMUM : 2 VALUES VALUE LINKING : && VALUE TYPE : DECIMAL NUMBER CONVERSION TYPE : BINARY NUMBER WITH 8 BITS POSSIBLE VALUES : 8-23 CIR = ;

But from 8 to 23 were circuit for the base station for the cmi v2.3 standard so i think it's a bug for the v4