Difference between revisions of "optiPoint 150 S Release Notes"
The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.
Line 27: | Line 27: | ||
|} | |} | ||
− | == | + | === Fixed Bugs and new features since Version 1.22 === |
+ | * Broadsoft: DHCP Trouble - phone couldn't obtain IP adress via DHCP shortly | ||
+ | * Broadsoft: Should not perform SRV lookup if service domain IPv4 format | ||
+ | * Broadsoft: Failover/failback mechanism | ||
+ | * IP: New default QoS L3 values (Signalling: AF31 (DSCP 26) and RTP: EF (DSCP 46)) | ||
+ | * HP3k: No Ringback tone when calling Upoe or HFA phone @ HP3k (complies now to RFC 3960 sect 3.2) | ||
+ | * Admin: Possible to configure Call forwarding at the phone when connected to HP3k, HP4k)Now neither WBM nor local admin can configure CF in this case (correct!) | ||
+ | * IP: Phone is sending out ARP requests for IP: 192.1.1.49 But this IP is NOWHERE configured in the phone. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
=== Fixed Bugs === | === Fixed Bugs === | ||
Line 82: | Line 46: | ||
! Comment | ! Comment | ||
|- | |- | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | - | ||
| N/A | | N/A | ||
| IP | | IP |
Revision as of 08:22, 28 September 2006
The optiPoint 150 S Release Notes describe descending sorted new features, fixed firmware bugs und open issues for appropriate firmware versions of the optiPoint 150 S ( optiPoint 150 S).
Contents
V1.28
What’s New?
Internal ID | Cluster | New feature | Comment |
---|---|---|---|
N/A | Sylantro | Special call park feature for Sylantro V4.0 | Fixed |
N/A | Sylantro | Special call pick-up feature for Sylantro V4.0 | Fixed |
N/A | Sylantro | Distinctive ringing for Sylantro V4.0 | Fixed |
Fixed Bugs and new features since Version 1.22
- Broadsoft: DHCP Trouble - phone couldn't obtain IP adress via DHCP shortly
- Broadsoft: Should not perform SRV lookup if service domain IPv4 format
- Broadsoft: Failover/failback mechanism
- IP: New default QoS L3 values (Signalling: AF31 (DSCP 26) and RTP: EF (DSCP 46))
- HP3k: No Ringback tone when calling Upoe or HFA phone @ HP3k (complies now to RFC 3960 sect 3.2)
- Admin: Possible to configure Call forwarding at the phone when connected to HP3k, HP4k)Now neither WBM nor local admin can configure CF in this case (correct!)
- IP: Phone is sending out ARP requests for IP: 192.1.1.49 But this IP is NOWHERE configured in the phone.
Fixed Bugs
Internal ID | Cluster | Problem | Comment |
---|---|---|---|
N/A | IP | Phone is sending out ARP requests for IP: 192.1.1.49 But this IP is NOWHERE configured in the phone. |
V1.25
Fixed Bugs
- General: Possibiliy to use special characters in SIP-ID like (@, /, %) needed for registration on some of the SIP providers.
V1.24
What’s New?
- Support of DNS query SRV (DNS_SRV)
- Support DNS TTL
- Support RFC 3264 Hold for Broadsoft
Fixed Bugs
- General: alphanumeric SIP_ID’s now possible (e.g. vorname.nachname@provider.com)
- General: Loud tone when call disconnected
- General: Calltransfer not possible after toggle between calls
- LAN: phone doesn’t register, if L2 QoS value is set
- LAN: VLAN ID can’t be reset to None
- HiPath 3000: Toggle between calls not possible
- HiPath 3000: Busy tone after attended Call transfer
- HiPath 3000: HP3k-HP3k trunking, no payload after transfer
- Phone GUI: Remove possibility to configure Call Forwarding when connected to HiPath 2000, HiPath 3000, HiPath 4000, HiPath 5000
Known & Open Issues
- HiPath 3000: Blind (semi-attended) transfer doesn’t work
- Not possible to dial, after first call was made with Hook on
- Symmetric use of UDP ports (planned for V1.25)
V1.23
What’s New?
- Telnet port disabled
- Distinctive Ringing (Sylantro) supported
V1.22
Internal ID | Cluster | New feature | Comment |
---|---|---|---|
323 | VLAN ID can't be configured via Phone | Fixed | |
356 | Blind transfer does not work oh H8000 | Fixed | |
358 | After factory reset it is still possible to log in as user defined in last saved configuration | Fixed | |
361 | Admin password is not reset after factory reset | Fixed | |
380 | Disable Telnet Access at the optiPoint 150 | Fixed |