− | Hallo,
| |
− | i'm on hipath 4000 v4.2_1 and hotfix 42 , on the pbx there's an Slc24 q2193-x200 with the last loadware pzdslc25 cv373
| |
− | the following error occoured:
| |
− | with
| |
− | res-dssuen,1-2-109-0;
| |
− | the system deactive the base station bs4 on circuit 0 so with dis-slcb:bssc,data,2,109,0;
| |
− | byte 12 &13 are 02 FF
| |
− | ad insert the following comment:
| |
| | | |
− | RES-DSSU:PEN,1-2-109-0;
| |
− | H500: AMO DSSU STARTED
| |
− | H33: PEN 1-2-109-0 WAS ALREADY DEACTIVATED
| |
− | H22: BASE STATION CAN BE LOADED ONLY BY MEANS OF
| |
− | EXEC-DSSU:1,2,109;
| |
− |
| |
− | but with the command exec-dssu:1,2,109; nothing happened
| |
− | i have to use act-dssu:aul,pen,1-2-109-0;
| |
− | the bs4 will be loaded correctly
| |
− |
| |
− | if i use the command line step by step this is the scenario:
| |
− |
| |
− | <ex-dssu:
| |
− | LTG = 1
| |
− | LTU = 2
| |
− | SLOT = 109
| |
− | CIR = 0
| |
− | M34: VALUE NOT WITHIN ADMISSIBLE RANGE
| |
− | CIR = ??
| |
− | CIR : CIRCUIT NUMBER
| |
− | CHARACTERISTIC : OPTIONAL
| |
− | MINIMUM : 1 VALUES
| |
− | MAXIMUM : 2 VALUES
| |
− | VALUE LINKING : &&
| |
− | VALUE TYPE : DECIMAL NUMBER
| |
− | CONVERSION TYPE : BINARY NUMBER WITH 8 BITS
| |
− | POSSIBLE VALUES : 8-23
| |
− | CIR = ;
| |
− |
| |
− | But from 8 to 23 were circuit for the base station for the cmi v2.3 standard
| |
− | so i think it's a bug for the v4
| |