(71 intermediate revisions by 9 users not shown) |
Line 1: |
Line 1: |
− | The '''optiPoint 150 S Release Notes''' describe descending sorted new features, fixed firmware bugs und open issues for appropriate firmware versions of the [[optiPoint 150 S]] ({{de}}[[optiPoint 150 S (de)|optiPoint 150 S]]).
| + | {{Breadcrumb|en|0|{{dev-en}}|optiPoint|optiPoint 150 S}} |
− | | + | {{Discontinued|en|Devices}} |
− | == V1.29 (still under validation)==
| |
− | | |
− | === What’s New? ===
| |
− | | |
− | * Be able to disable *99 at Sylantro
| |
− | | |
− | === Fixed Bugs ===
| |
− | | |
− | * Wrong display message at Op150 after call transfer
| |
− | * No Fallback to Inband DTMF if RFC2833 configured but one partner does not support DTMF after RFC2833
| |
− | * Number not dialed when going Off Hook
| |
− | * Phone plays DTMF digits if called while dialing.
| |
− | * Providertest Web.de: No Registration with DNS Name for SIP Server
| |
− | * Special characters like <nowiki>-</nowiki> and <nowiki>/</nowiki> are now possible to be entered under SIP setup/ SIP settings in the Web based management.
| |
− | | |
− | == V1.28 ==
| |
− | | |
− | === What’s New? ===
| |
− | {| {{DefaultTable}} | |
− | ! Internal ID
| |
− | ! Cluster
| |
− | ! New feature
| |
− | ! Comment
| |
− | |- | |
− | | N/A
| |
− | | Sylantro
| |
− | | Special call park feature for Sylantro V4.0
| |
− | | Fixed
| |
− | |-
| |
− | | N/A
| |
− | | Sylantro
| |
− | | Special call pick-up feature for Sylantro V4.0
| |
− | | Fixed
| |
− | |-
| |
− | | N/A
| |
− | | Sylantro
| |
− | | Distinctive ringing for Sylantro V4.0
| |
− | | Fixed
| |
− | |-
| |
− | |} | |
− | | |
− | === Fixed Bugs and new features since Version 1.22 ===
| |
− | * Broadsoft: DHCP Trouble - phone couldn't obtain IP adress via DHCP shortly
| |
− | * Broadsoft: Should not perform SRV lookup if service domain IPv4 format
| |
− | * Broadsoft: Failover/failback mechanism
| |
− | * Broadsoft: Support RFC 3264 Hold for Broadsoft
| |
− | * IP: New default QoS L3 values (Signalling: AF31 (DSCP 26) and [[RTP]]: EF (DSCP 46)
| |
− | * Admin: Possible to configure Call forwarding at the phone when connected to HP3k, HP4k)Now neither WBM nor local admin can configure CF in this case
| |
− | * General: Possibiliy to use special characters in SIP-ID like (@, /, %) needed for registration on some of the SIP providers.
| |
− | * Support of DNS query SRV (DNS_SRV)
| |
− | * General: alphanumeric SIP_ID’s now possible (e.g. vorname.nachname@provider.com)
| |
− | * General: Short loud tone when call disconnected (after hook-on for about 200 ms)
| |
− | * General: Calltransfer not possible after toggle between calls
| |
− | * General: The "Port field" in the SIP settings should aleady have a default value 5060.
| |
− | * General: To stay conform with other Siemens phones the default Codec Settings of the OP150S should be changed to "G.711A > G.711U > G.72x"
| |
− | * General: Not possible to dial after first call was made with Hook on.
| |
− | * General: Telnet access to optiPoint 150 S
| |
− | * LAN: phone doesn’t register, if L2 QoS value is set
| |
− | * LAN: VLAN ID can’t be reset to None
| |
− | * HiPath 3000: Toggle between calls not possible
| |
− | * HiPath 3000: Do not disturb is not working
| |
− | * HiPath 3000: No Ringback tone when calling Upoe or HFA phone @ HP3k (complies now to RFC 3960 sect 3.2)
| |
− | | |
− | * HiPath 3000: Busy tone after attended Call transfer
| |
− | * HiPath 3000: HP3k-HP3k trunking, no payload after transfer
| |
− | * Phone GUI: Remove possibility to configure Call Forwarding when connected to HiPath 2000, HiPath 3000, HiPath 4000, HiPath 5000
| |
− | * Telnet port disabled
| |
− | * Sylantro: Distinctive Ringing (Sylantro) supported
| |
− | | |
− | === Known & Open Issues ===
| |
− | * HiPath 3000: Blind (semi-attended) transfer doesn’t work
| |
− | * Not possible to dial, after first call was made with Hook on
| |
− | * Symmetric use of UDP ports
| |
− | | |
− | == V1.22 ==
| |
− | | |
− | Fixed Bugs and new features:
| |
− | | |
− | * VLAN ID can't be configured via Phone
| |
− | * Blind transfer does not work oh H8000
| |
− | * After factory reset it is still possible to log in as user defined in last saved configuration
| |
− | * Admin password is not reset after factory reset
| |
− | * Disable Telnet Access at the optiPoint 150
| |