Hallo,
+
#REDIRECT [[HiPath Cordless IP]]
−
i'm on hipath 4000 v4.2_1 and hotfix 42 , on the pbx there's an Slc24 q2193-x200 with the last loadware pzdslc25 cv373
 
−
the following error occoured:
 
−
with
 
−
res-dssuen,1-2-109-0;
 
−
the system deactive the base station bs4 on circuit 0 so with dis-slcb:bssc,data,2,109,0;
 
−
byte 12 &13 are 02 FF
 
−
ad insert the following comment:
 
−
 
 
−
RES-DSSU:PEN,1-2-109-0;
 
−
H500: AMO DSSU STARTED
 
−
H33: PEN 1-2-109-0 WAS ALREADY DEACTIVATED
 
−
H22: BASE STATION CAN BE LOADED ONLY BY MEANS OF
 
−
EXEC-DSSU:1,2,109;
 
−
 
 
−
but with the command exec-dssu:1,2,109; nothing happened
 
−
i have to use act-dssu:aul,pen,1-2-109-0;
 
−
the bs4 will be loaded correctly
 
−
 
 
−
if i use the command line step by step this is the scenario:
 
−
 
 
−
<ex-dssu:
 
−
LTG = 1
 
−
LTU = 2
 
−
SLOT = 109
 
−
CIR = 0
 
−
M34: VALUE NOT WITHIN ADMISSIBLE RANGE
 
−
CIR = ??
 
−
CIR : CIRCUIT NUMBER
 
−
CHARACTERISTIC : OPTIONAL
 
−
MINIMUM : 1 VALUES
 
−
MAXIMUM : 2 VALUES
 
−
VALUE LINKING : &&
 
−
VALUE TYPE : DECIMAL NUMBER
 
−
CONVERSION TYPE : BINARY NUMBER WITH 8 BITS
 
−
POSSIBLE VALUES : 8-23
 
−
CIR = ;
 
−
 
 
−
But from 8 to 23 were circuit for the base station for the cmi v2.3 standard
 
−
so i think it's a bug for the v4
 