| − | Hallo,
  |   | 
| − | i'm on hipath 4000 v4.2_1 and hotfix 42 , on the pbx there's an Slc24 q2193-x200 with the last loadware pzdslc25 cv373
  |   | 
| − | the following error occoured:
  |   | 
| − | with
  |   | 
| − | res-dssuen,1-2-109-0;
  |   | 
| − | the system deactive the base station bs4 on circuit 0 so with dis-slcb:bssc,data,2,109,0;
  |   | 
| − | byte 12 &13 are 02 FF
  |   | 
| − | ad insert the following comment:
  |   | 
|   |  |   |  | 
| − | RES-DSSU:PEN,1-2-109-0;
  |   | 
| − | H500: AMO DSSU STARTED
  |   | 
| − | H33: PEN 1-2-109-0 WAS ALREADY DEACTIVATED
  |   | 
| − | H22: BASE STATION CAN BE LOADED ONLY BY MEANS OF
  |   | 
| − | EXEC-DSSU:1,2,109;
  |   | 
| − | 
  |   | 
| − | but with the command exec-dssu:1,2,109; nothing happened
  |   | 
| − | i have to use act-dssu:aul,pen,1-2-109-0;
  |   | 
| − | the bs4 will be loaded correctly
  |   | 
| − | 
  |   | 
| − | if i use the command line step by step this is the scenario:
  |   | 
| − | 
  |   | 
| − | <ex-dssu:
  |   | 
| − | LTG = 1
  |   | 
| − | LTU = 2
  |   | 
| − | SLOT = 109
  |   | 
| − | CIR = 0
  |   | 
| − | M34: VALUE NOT WITHIN ADMISSIBLE RANGE
  |   | 
| − | CIR = ??
  |   | 
| − | CIR : CIRCUIT NUMBER
  |   | 
| − | CHARACTERISTIC : OPTIONAL
  |   | 
| − | MINIMUM : 1 VALUES
  |   | 
| − | MAXIMUM : 2 VALUES
  |   | 
| − | VALUE LINKING : &&
  |   | 
| − | VALUE TYPE : DECIMAL NUMBER
  |   | 
| − | CONVERSION TYPE : BINARY NUMBER WITH 8 BITS
  |   | 
| − | POSSIBLE VALUES : 8-23
  |   | 
| − | CIR = ;
  |   | 
| − | 
  |   | 
| − | But from 8 to 23 were circuit for the base station for the cmi v2.3 standard
  |   | 
| − | so i think it's a bug for the v4
  |   |