Views

Difference between revisions of "optiPoint power supply and PoE classes"

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Jump to: navigation, search
(IP workpoints Power Supply methods)
 
(13 intermediate revisions by 3 users not shown)
Line 1: Line 1:
The tables show the availability and class of Power over Ethernet ([[PoE]]) on [[optiPoint]] IP phones.
+
{{Breadcrumb|0|0|{{dev-en}}}}
 
+
The tables below show the availability and class of Power over Ethernet ([[PoE]]) of [[optiPoint]] IP phones.
Find the [[SIP V6.0 optiPoint compatibility#Part number|part number]] on the nameplate on the underside of the telephone. See the * as wildcard for the device version.
 
 
 
 
__TOC__
 
__TOC__
 +
== IP workpoints Power Supply methods ==
  
== IP workpoints Power Supply methods ==
 
 
The optiPoint IP workpoints can be powered using different methods as listed in the following table:
 
The optiPoint IP workpoints can be powered using different methods as listed in the following table:
  
 
{| {{DefaultTable}}
 
{| {{DefaultTable}}
 
! IP workpoint power supply method
 
! IP workpoint power supply method
! optiPoint 150
+
! optiPoint 400<ref name="phasedout">[[Phase-out|Phased out]].</ref>
! optiPoint 400
+
! optiPoint 410<ref name="op410_420_PoE_FAQ">See also IEEE802.3af Standard ([[PoE]]) related FAQ on the [[optiPoint_410/420_FAQ_%28general%29|optiPoint 410/420 FAQ (General)]] page.</ref>
! optiPoint 410<ref name="op410_420_PoE_FAQ"><br \>See also IEEE802.3af Standard ([[PoE]]) related FAQ on the [[optiPoint_410/420_FAQ_%28general%29|optiPoint 410/420 FAQ (General)]] page.</ref>
 
 
! optiPoint 420<ref name="op410_420_PoE_FAQ" />
 
! optiPoint 420<ref name="op410_420_PoE_FAQ" />
! optiPoint 600
+
! optiPoint 600<ref name="phasedout" />
! AP1120<ref name="AP1120"><br \>HiPath [[AP 1120]] no longer supports IEEE802.3af Standard ([[PoE]]), local AC/DC Power Supply unit is now included with each access device.</ref>
+
! AP1120<ref name="AP1120">HiPath [[AP 1120]] no longer supports IEEE802.3af Standard ([[PoE]]), local AC/DC Power Supply unit is now included with each access device.</ref>
 
|-
 
|-
 
| AC/DC Power Supply unit
 
| AC/DC Power Supply unit
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
 
 
|-
 
|-
 
| Pre-standard IEEE 802.3af mid span PoE injectors
 
| Pre-standard IEEE 802.3af mid span PoE injectors
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}<ref name="optiPoint400">The optiPoint 400 must be supplied with a PowerHub compliant with IEC 60950 regulation. The optiPoint 400 supports a pre-Standard IEEE 802.3af configuration that requires an 8 wires cable (Ethernet cable) using spare pairs as indicated on the table below.</ref>
| align="center" style="background:#e0ffe0" | Yes<ref name="optiPoint400"><br \>The optiPoint 400 must be supplied with a PowerHub compliant with IEC 60950 regulation.<br/>The optiPoint 400 supports a pre-Standard IEEE 802.3af configuration that requires an 8 wires cable (Ethernet cable) using spare pairs as indicated on the table below.</ref>
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | -
| align="center" style="background:#ffe0e0" | No
 
 
|-
 
|-
 
| IEEE 802.3af mid span (via unused pairs)
 
| IEEE 802.3af mid span (via unused pairs)
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | -
| align="center" style="background:#ffe0e0" | No
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | -
| align="center" style="background:#ffe0e0" | No
 
 
|-
 
|-
 
| IEEE 802.3af end span (via used pairs)
 
| IEEE 802.3af end span (via used pairs)
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | -
| align="center" style="background:#ffe0e0" | No
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | -
| align="center" style="background:#ffe0e0" | No
+
| style="text-align:center;" | -
| align="center" style="background:#ffe0e0" | No
 
 
|-
 
|-
 
| CISCO Power over LAN (via used pairs)
 
| CISCO Power over LAN (via used pairs)
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | -
| align="center" style="background:#ffe0e0" | No
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | {{yes}}
| align="center" style="background:#e0ffe0" | Yes
+
| style="text-align:center;" | -
| align="center" style="background:#ffe0e0" | No
 
|-
 
 
|}
 
|}
  
 
<references />
 
<references />
  
optiPoint 400 cabling Pin / Signal assignment table for correct [[PoE]] operation
+
'''optiPoint 400 cabling Pin / Signal assignment table for correct [[PoE]] operation''':
  
 
{| {{prettytable}}
 
{| {{prettytable}}
 
|- style="font-size:8pt" valign="center" halign="center"  
 
|- style="font-size:8pt" valign="center" halign="center"  
| align="center" | Pin
+
| style="text-align:center;" | Pin
| align="center" | 1
+
| style="text-align:center;" | 1
| align="center" | 2
+
| style="text-align:center;" | 2
| align="center" | 3
+
| style="text-align:center;" | 3
| align="center" | 4
+
| style="text-align:center;" | 4
| align="center" | 5
+
| style="text-align:center;" | 5
| align="center" | 6
+
| style="text-align:center;" | 6
| align="center" | 7
+
| style="text-align:center;" | 7
| align="center" | 8
+
| style="text-align:center;" | 8
 
|- style="font-size:8pt" valign="center" haligh="center"
 
|- style="font-size:8pt" valign="center" haligh="center"
| align="center" | Signal
+
| style="text-align:center;" | Signal
| align="center" | TXD +
+
| style="text-align:center;" | TXD +
| align="center" | TXD -
+
| style="text-align:center;" | TXD -
| align="center" | RXD +
+
| style="text-align:center;" | RXD +
| align="center" | PoL +
+
| style="text-align:center;" | PoL +
| align="center" | PoL +
+
| style="text-align:center;" | PoL +
| align="center" | RXD -
+
| style="text-align:center;" | RXD -
| align="center" | PoL -
+
| style="text-align:center;" | PoL -
| align="center" | PoL -
+
| style="text-align:center;" | PoL -
 
|}
 
|}
  
 
=== AC/DC Power Supply unit ===
 
=== AC/DC Power Supply unit ===
  
==== General informations ====
+
AC/DC Power Supply units ...
 
+
* are available as external adapters for indoor use only, they could be used to supply IP workpoints should [[PoE]] not be available or not be used.
AC/DC Power Supply units are available as external adapters for indoor use only, they could be used to supply IP workpoints should [[PoE]] not be available or not be used.
+
* must be ordered ''separately'' from the IP workpoint device once required, please refer to each product's documentation to find them.
 
+
* are optional accessory with specific Part Numbers, some of them are available in country specific variants such: ''EU'', ''US'' (110V A.C.) and ''UK''.
AC/DC Power Supply units must be ordered ''separately'' from the IP workpoint device once required, please refer to each product's documentation to find them.
 
 
 
AC/DC Power Supply units are optional accessory with specific Part Numbers, some of them are available in country specific variants such:
 
* EU
 
* US (110V A.C.)
 
* UK
 
  
 
==== optiPoint 600 ====
 
==== optiPoint 600 ====
Line 106: Line 91:
  
 
As shown in the table above there are four different methods to feed power to IP workpoint.
 
As shown in the table above there are four different methods to feed power to IP workpoint.
Not all of these methods are supported on every workpoints (See, as examples, differences about [[optiPoint 150 S]], optiPoint 400, optiPoint 600 and HiPath [[AP 1120]]).
+
Not all of these methods are supported on every workpoints (See, as examples, differences about [[optiPoint 150 S]], optiPoint 400, optiPoint 600 and [[HiPath AP 1120]]).
  
 
* Pre-Standard '''IEEE 802.3af''' mid span [[PoE]] injectors (known also as power hubs) via spare pairs wires of Ethernet cabling infrastructure.
 
* Pre-Standard '''IEEE 802.3af''' mid span [[PoE]] injectors (known also as power hubs) via spare pairs wires of Ethernet cabling infrastructure.
Line 116: Line 101:
 
As such, it is a scalable solution for ''upgrading'' an existing network infrastructure to support Power over Ethernet.
 
As such, it is a scalable solution for ''upgrading'' an existing network infrastructure to support Power over Ethernet.
  
== optiPoint 150 S ==
+
== Supported optiPoint devices ==  
 +
 
 +
Find the [[SIP V6.0 optiPoint compatibility#Part number|part number]] on the nameplate on the underside of the telephone. See the * as wildcard for the device version.
  
{| {{DefaultTable}}
+
For OpenStage devices see [[OpenStage power supply and PoE classes]].
! Name of Phone
 
! Housing color
 
! width="150" | Part number
 
! [[PoE#PoE classes|PoE class]]
 
|-
 
| optiPoint 150 S
 
| Manganese
 
| L30250-F600-A849-*
 
| 2
 
|}
 
  
== optiPoint 410 ==
+
=== optiPoint 410 ===
  
 
{| {{DefaultTable}}
 
{| {{DefaultTable}}
Line 235: Line 212:
 
| S30817-S7212-M101-*
 
| S30817-S7212-M101-*
 
| * &ge; 1
 
| * &ge; 1
| 0
+
| 1
 
| -
 
| -
 
| -
 
| -
Line 254: Line 231:
 
| S30817-S7212-M107-*
 
| S30817-S7212-M107-*
 
| * &ge; 1
 
| * &ge; 1
| 0
+
| 1
 
| -
 
| -
 
| -
 
| -
Line 337: Line 314:
 
|}
 
|}
  
== optiPoint 420 ==
+
=== optiPoint 420 ===
  
 
{| {{DefaultTable}}
 
{| {{DefaultTable}}

Latest revision as of 09:19, 17 December 2014

The tables below show the availability and class of Power over Ethernet (PoE) of optiPoint IP phones.

IP workpoints Power Supply methods

The optiPoint IP workpoints can be powered using different methods as listed in the following table:

IP workpoint power supply method optiPoint 400[1] optiPoint 410[2] optiPoint 420[2] optiPoint 600[1] AP1120[3]
AC/DC Power Supply unit tick.gif tick.gif tick.gif tick.gif tick.gif
Pre-standard IEEE 802.3af mid span PoE injectors tick.gif[4] tick.gif tick.gif tick.gif -
IEEE 802.3af mid span (via unused pairs) - tick.gif tick.gif tick.gif -
IEEE 802.3af end span (via used pairs) - tick.gif tick.gif - -
CISCO Power over LAN (via used pairs) - tick.gif tick.gif tick.gif -
  1. 1.0 1.1 Phased out.
  2. 2.0 2.1 See also IEEE802.3af Standard (PoE) related FAQ on the optiPoint 410/420 FAQ (General) page.
  3. HiPath AP 1120 no longer supports IEEE802.3af Standard (PoE), local AC/DC Power Supply unit is now included with each access device.
  4. The optiPoint 400 must be supplied with a PowerHub compliant with IEC 60950 regulation. The optiPoint 400 supports a pre-Standard IEEE 802.3af configuration that requires an 8 wires cable (Ethernet cable) using spare pairs as indicated on the table below.

optiPoint 400 cabling Pin / Signal assignment table for correct PoE operation:

Pin 1 2 3 4 5 6 7 8
Signal TXD + TXD - RXD + PoL + PoL + RXD - PoL - PoL -

AC/DC Power Supply unit

AC/DC Power Supply units ...

  • are available as external adapters for indoor use only, they could be used to supply IP workpoints should PoE not be available or not be used.
  • must be ordered separately from the IP workpoint device once required, please refer to each product's documentation to find them.
  • are optional accessory with specific Part Numbers, some of them are available in country specific variants such: EU, US (110V A.C.) and UK.

optiPoint 600

The optiPoint 600 workpoint must always be powered from a local power supply in the TDM mode, It may be powered locally or via PoE when used in the IP (CorNet-IP) mode.
The optiPoint 600 uses the same local power supply available for the optiPoint 500 and optiset E families.

Power over Ethernet (PoE)

As shown in the table above there are four different methods to feed power to IP workpoint. Not all of these methods are supported on every workpoints (See, as examples, differences about optiPoint 150 S, optiPoint 400, optiPoint 600 and HiPath AP 1120).

  • Pre-Standard IEEE 802.3af mid span PoE injectors (known also as power hubs) via spare pairs wires of Ethernet cabling infrastructure.
  • IEEE 802.3af Standard mid span (unused pair wires) as provided by the current and pre-Standard power hubs
  • IEEE 802.3af Standard end span (used pair wires) as provided by all data vendors from their Ethernet switches (including CISCO)
  • CISCO pre-standard (used pair wires) inline power as installed in many older Ethernet switches.

Power over Ethernet mid span (Power over Ethernet injector) is connected in cascade to exisintg Ethernet Switch or Hub devices. As such, it is a scalable solution for upgrading an existing network infrastructure to support Power over Ethernet.

Supported optiPoint devices

Find the part number on the nameplate on the underside of the telephone. See the * as wildcard for the device version.

For OpenStage devices see OpenStage power supply and PoE classes.

optiPoint 410

Name of Phone Housing color Part number Device Version PoE class Device Version PoE class
optiPoint 410 entry arctic S30817-S7201-A101-* * ≥ 1 0 - -
S30817-S7201-L101-* * ≥ 1 0 - -
S30817-S7201-M101-* * ≥ 1 0 - -
mangan S30817-S7201-A107-* * ≥ 1 0 - -
S30817-S7201-L107-* * ≥ 1 0 - -
S30817-S7201-M107-* * ≥ 1 0 - -
optiPoint 410 economy arctic S30817-S7202-A101-* * ≤ 13 0 * ≥ 14 1
S30817-S7202-L101-* * ≥ 1 1 - -
S30817-S7202-M101-* * ≥ 1 0 - -
mangan S30817-S7202-A107-* * ≤ 19 0 * ≥ 20 1
S30817-S7202-L107-* * ≥ 1 1 - -
S30817-S7202-M107-* * ≥ 1 1 - -
optiPoint 410 eco plus arctic S30817-S7212-A101-* * ≥ 1 1 - -
S30817-S7212-L101-* * ≥ 1 1 - -
S30817-S7212-M101-* * ≥ 1 1 - -
mangan S30817-S7212-A107-* * ≥ 1 1 - -
S30817-S7212-L107-* * ≥ 1 1 - -
S30817-S7212-M107-* * ≥ 1 1 - -
optiPoint 410 standard arctic S30817-S7203-A101-* * ≤ 13 0 * ≥ 14 2
S30817-S7203-L101-* * ≥ 1 2 - -
S30817-S7203-M101-* * ≥ 1 2 - -
mangan S30817-S7203-A107-* * ≤ 21 0 * ≥ 22 2
S30817-S7203-L107-* * ≥ 1 2 - -
S30817-S7203-M107-* * ≥ 1 2 - -
optiPoint 410 advance arctic S30817-S7204-A101-* * ≤ 11 0 * ≥ 12 2
S30817-S7204-L101-* * ≥ 1 2 - -
S30817-S7204-M101-* * ≥ 1 2 - -
mangan S30817-S7204-A107-* * ≤ 16 0 * ≥ 17 2
S30817-S7204-L107-* * ≥ 1 2 - -
S30817-S7204-M107-* * ≥ 1 2 - -

optiPoint 420

Name of Phone Housing color Part number Device Version PoE class Device Version PoE class
optiPoint 420 economy arctic S30817-S7209-A101-* * ≤ 2 0 * ≥ 3 1
S30817-S7209-L101-* * ≥ 1 1 - -
S30817-S7209-M101-* * ≥ 1 1 - -
mangan S30817-S7209-A107-* * ≤ 2 0 * ≥ 3 1
S30817-S7209-L107-* * ≥ 1 1 - -
S30817-S7209-M107-* * ≥ 1 1 - -
optiPoint 420 eco plus arctic S30817-S7210-A101-* * ≥ 1 1 - -
S30817-S7210-L101-* * ≥ 1 1 - -
S30817-S7210-M101-* * ≥ 1 1 - -
mangan S30817-S7210-A107-* * ≥ 1 1 - -
S30817-S7210-L107-* * ≥ 1 1 - -
S30817-S7210-M107-* * ≥ 1 1 - -
optiPoint 420 standard arctic S30817-S7211-A101-* * ≥ 1 2 - -
S30817-S7211-L101-* * ≥ 1 2 - -
S30817-S7211-M101-* * ≥ 1 2 - -
mangan S30817-S7211-A107-* * ≥ 1 2 - -
S30817-S7211-L107-* * ≥ 1 2 - -
S30817-S7211-M107-* * ≥ 1 2 - -
optiPoint 420 advance arctic S30817-S7207-A101-* * ≤ 12 0 * ≥ 13 2
S30817-S7207-L101-* * ≥ 1 2 - -
S30817-S7207-M101-* * ≥ 1 2 - -
mangan S30817-S7207-A107-* * ≤ 10 0 * ≥ 11 2
S30817-S7207-L107-* * ≥ 1 2 - -
S30817-S7207-M107-* * ≥ 1 2 - -