In order to upgrade the optiPoint WL2 professional V1 from a Step 1 software version (50.001.36 as example) to a Step 2 software version (50.002.32 as example) is mandatory to follow a step by step procedure described in detail below:
+
In order to upgrade the [[optiPoint WL2 professional]] V1 from a Step 1 software version (50.001.36 as example) to a Step 2 software version (50.002.32 as example) is mandatory to follow a step by step procedure described in detail below:
  
 
The Step 2 software versions (50.002.xx) require both a data file system upgrade and a display language upgrade in order to work so there are specialized intermediate software versions both for application software and language software.
 
The Step 2 software versions (50.002.xx) require both a data file system upgrade and a display language upgrade in order to work so there are specialized intermediate software versions both for application software and language software.

Revision as of 11:01, 6 July 2007

In order to upgrade the optiPoint WL2 professional V1 from a Step 1 software version (50.001.36 as example) to a Step 2 software version (50.002.32 as example) is mandatory to follow a step by step procedure described in detail below:

The Step 2 software versions (50.002.xx) require both a data file system upgrade and a display language upgrade in order to work so there are specialized intermediate software versions both for application software and language software.

Follow these steps:

  • Backup your optiPoint WL2 professional settings via WBM.
  • Check your optiPoint WL2 professional software version (it should be 50.001.xx or older) before proceeding.
  • Update via WBM to the intermediate software version named "prep50_2_27_Std.img" (Siemens).
  • Update via WBM to the intermediate software version named "WL2_AdminLanguageFix.img" in order to fix the language.
  • Update via WBM to the final software version named "swup50-002-34-00070.img" (50.002.34 as latest software version available).

Keep in mind that an upgrade without these intermediate software versions is not possible: the version check will ends with the message "Failed" if the procedure above will not be followed.

Between intermediate upgrade steps, when the optiPoint WL2 professional starts up with this version, the factory data file system content is set to the default values of a standard HFA version and the default ringer tones and images are copied to the data file systems.

After each reboot of the optiPoint WL2 professional the following message will be displayed on its display:

Temp. SW only!

Please Update!

Such warning message can be confirmed selecting "OK" but it's neither necessary nor mandatory to select "OK" (and so confirm it) for the update to reach the final software version.