== Important information ==
+
{{Discontinued|en|Devices}}
  
=== General Info for all Version ===
 
  
*'''IMPORTANT''': If there where seen Link Flaps on the Ethernet Switch when the Phone is powered off. Please try to configure the Switch to 100 Mbit full- or half- duplex static. In some cases this error was solved with this configuration.
+
Information to V5.1 of the [[optiPoint 410/420]] CorNet-IP ([[HFA]]) phone family.
* [[Codec#G.722|G.722]] CoDec is used with [[DMC]] (Direct Media Connection) between two optiPoint 410 IP phones only. ([[DMC]] feature must be activated)  
+
 
 +
== General Info for all Releases ==
 +
 
 +
{{Warning
 +
|If there where seen Link Flaps on the Ethernet Switch when the Phone is powered off, please try to configure the Switch to 100 Mbit full- or half- duplex static. In some cases this error was solved with this configuration.
 +
}}
 +
* Payload Security is only possible with the [[optiPoint 410/420]] eco+/std/adv
 +
* [[Codec#G.722|G.722]] CoDec is used with [[DMC]] (Direct Media Connection) between two optiPoint 4X0 IP phones only ([[DMC]] feature must be activated).
 
* A call via Gateway never uses [[Codec#G.722|G.722]].
 
* A call via Gateway never uses [[Codec#G.722|G.722]].
* If “High Quality pref.” is entered, [[Codec#G.722|G.722]] calls to other OP410 are possible, but only [[Codec#G.711|G.711]] calls to other phones (OP600 and OP400). Because of this the users get a different impression of quality.  
+
* If “High Quality pref.” is entered, [[Codec#G.722|G.722]] calls to other OP4X0 or OpenStage HFA are possible, but only [[Codec#G.711|G.711]] calls to other phones. Because of this the users get a different impression of quality.  
 
* It is highly recommended to deactivate both [[VAD]] (Voice Activity Detection) and Silence Suppression features.
 
* It is highly recommended to deactivate both [[VAD]] (Voice Activity Detection) and Silence Suppression features.
 
* To upgrade via [[NetBoot]] the Key 3 have to be pressed while powering up the phone until the phone starts to load the image.
 
* To upgrade via [[NetBoot]] the Key 3 have to be pressed while powering up the phone until the phone starts to load the image.
 
* Netboot Upgrade via Remote is only possible with V5 R1.33.0 or later.
 
* Netboot Upgrade via Remote is only possible with V5 R1.33.0 or later.
 +
* DHCP Leasetime: The recommended minimum leasetime is 8min as the RFC2131 is quite unclear about how long a leasetime should be as a minimum. <br /> See section 4.4.5 Reacquisition and expiration <br /> "In both RENEWING and REBINDING states, if the client receives no response to its DHCPREQUEST message, the client SHOULD wait one-half of the remaining time until T2 (in RENEWING state) and one-half of the remaining lease time (in REBINDING state), down to a minimum of 60 seconds, before retransmitting the DHCPREQUEST message."
 +
 +
== Since Release [[optiPoint 410/420 Release Notes#V5 R1.33.0|V5 R1.33.0]] or later ==
 +
 +
{{Warning
 +
|At the moment there is a level 1 priority Bug at the HiPath DLS in combination with the NEW Version string.<br />At the Software Deployment in the DLS you can’t update more than one phone at the same time.<br/>'''This Bug is solved with the''' [[DLS|HiPath DLS V1.0 R1.27.0]] (HI-DLS.10.199.41) version.
 +
}}
  
==== Since Version [[optiPoint 410/420 Release Notes#V5 R1.33.0|V5 R1.33.0]] or later ====
+
== Since Release [[optiPoint 410/420 Release Notes#V5 R1.34.0|V5 R1.34.0]] or later ==
*'''IMPORTANT!!''' At the moment there is a level 1 priority Bug at the HiPath DLS in combination with the NEW Version string.<br /> At the Software Deployment in the DLS you can’t update more than one phone at the same time.<br/> '''This Bug is solved with the''' [[DLS|HiPath DLS V1.0 R1.27.0]] (HI-DLS.10.199.41) version.
 
*'''IMPORTANT!!''' It is REQUIRED to update to Version V5 R1.33.0 for every version ≤ V5.1.32.<br/> If this is not done no upgrade will be possible anymore because of the Version string changes, Security Check in the phone software.
 
*:''Example:''
 
::Update from V5.1.30 to V5 R1.33.000 is possible
 
::Update from V5.1.30 to V5 R1.34.000 is '''NOT''' possible
 
::Update from V5 R1.33.000 to V5 R1.35.000 is possible
 
  
==== Since Version [[optiPoint 410/420 Release Notes#V5 R1.34.0|V5 R1.34.0]] or later ====
 
 
*Now the Software comprised the [[AGP]] (Application Generic Platform) functionality including [[XML]] Applications support.<br /> This functionality will be only released project specific for prototype of corresponding applications.<br /> The [[AGP]] feature works only with a [[optiPoint application module]] connected.
 
*Now the Software comprised the [[AGP]] (Application Generic Platform) functionality including [[XML]] Applications support.<br /> This functionality will be only released project specific for prototype of corresponding applications.<br /> The [[AGP]] feature works only with a [[optiPoint application module]] connected.
  
==== Since Version [[optiPoint 410/420 Release Notes#V5 R1.35.0|V5 R1.35.0]] or later ====
+
== Since Release [[optiPoint 410/420 Release Notes#V5 R1.35.0|V5 R1.35.0]] or later ==
  
*'''IMPORTANT''': to make a bulk deployment of optiPoint 410/420 adopting the new [[New Software Versioning scheme|Version String Vx[.y] Rm.f.h]] scheme through the [[DLS]] tool it's mandatory to use [[DLS|HiPath DLS V1.0 R1.27.0]] (HI-DLS.10.199.41) version or higher.
+
{{Warning
 +
|To make a bulk deployment of optiPoint 410/420 adopting the new [[New Software Versioning scheme|Version String Vx[.y] Rm.f.h]] scheme through the [[DLS]] tool it's mandatory to use [[DLS|HiPath DLS V1.0 R1.27.0]] (HI-DLS.10.199.41) version or higher.
 +
}}
  
==== Since Version [[optiPoint 410/420 Release Notes#V5 R1.35.1|V5 R1.35.1]] or later ====
+
== Since Release [[optiPoint 410/420 Release Notes#V5 R1.35.1|V5 R1.35.1]] or later ==
  
 
*Used RTP port base from Port 5004 to 5013.<br/> Now the ports are used from the lowest configured Port to the highest.  
 
*Used RTP port base from Port 5004 to 5013.<br/> Now the ports are used from the lowest configured Port to the highest.  
Line 34: Line 42:
 
::5006 for RTP the Slave channel to B partner.
 
::5006 for RTP the Slave channel to B partner.
 
::5007 for RTCP the Slave channel to B partner.
 
::5007 for RTCP the Slave channel to B partner.
 +
 +
== Since Release [[optiPoint 410/420 Release Notes#V5 R2.36.4|V5 R2.36.4]] or later ==
 +
 +
* The TimeSetting Configuration has been changed. <br/> For further detail please have a look at this PDF document:<br/> {{File-DL|Time_Settings_since_Version_V5_R2.36.4|pdf}}
 +
 +
== Since Release [[optiPoint 410/420 Release Notes#V5 R4.6.0|V5 R4.6.0]] or later ==
 +
 +
* Implementation of the RQ00026068/RQ00026067. EAPOL-Logoff function is now working without activation of [[IEEE 802.1x]].
 +
 +
{{Warning
 +
|Security Step 1 is only supported with Hardware that has a equal or less Part Number then following:
 +
*optiPoint 410 entry S30817-S7201-A101-25 Arctic
 +
*optiPoint 410 entry S30817-S7201-A107-32 Mangan
 +
*optiPoint 410 economy S30817-S7202-A101-25 Arctic
 +
*optiPoint 410 economy S30817-S7202-A107-31 Mangan
 +
*optiPoint 410 eco plus S30817-S7212-A101-19 Arctic
 +
*optiPoint 410 eco plus S30817-S7212-A107-19 Mangan
 +
*optiPoint 410 standard S30817-S7203-A101-27 Arctic
 +
*optiPoint 410 standard S30817-S7203-A107-35 Mangan
 +
*optiPoint 410 advance S30817-S7204-A101-27 Arctic
 +
*optiPoint 410 advance S30817-S7204-A107-32 Mangan
 +
*optiPoint 420 eco S30817-S7209-A101-15 Arctic
 +
*optiPoint 420 eco S30817-S7209-A107-16 Mangan
 +
*optiPoint 420 eco plus S30817-S7210-A101-16 Arctic
 +
*optiPoint 420 eco plus S30817-S7210-A107-17 Mangan
 +
*optiPoint 420 standard S30817-S7211-A101-16 Arctic
 +
*optiPoint 420 standard S30817-S7211-A107-17 Mangan
 +
*optiPoint 420 adv. S30817-S7207-A101-25 Arctic
 +
*optiPoint 420 adv. S30817-S7207-A107-23 Mangan
 +
}}
 +
 +
== Since Release [[optiPoint 410/420 Release Notes#V5 R5.2.0|V5 R5.2.0]] or later ==
 +
 +
{{Warning|
 +
*Security Step 1 is not supported in this Bind, because of the support for SPE
 +
*The dowload capability for JAVA midlets is not longer supported. Do to the fact that Java midlets are out of support
 +
}}
 +
* For Mobile HFA please use the following Patch sets at the H4K - s20439 (H30160); s20419 (H30910);  s20440 (H30966).
 +
 +
== Since Release [[optiPoint 410/420 Release Notes#V5 R4.7.0|V5 R4.7.0]] or later ==
 +
 +
{{Warning
 +
|IMPORTANT!! There are new restrictions for the 802.1x feature
 +
}}
 +
For the certificate creation the are restrictions for the max. size of certificate.
 +
*Phone certificate the max. size is 2048 bytes.
 +
*Radius & root certificate the max. size is 4096 bytes.
 +
 +
== [[optiPoint 410/420 Release Notes#V5 R5.4.0|V5 R5.4.0]] ==
 +
{{Warning
 +
|If you are using the plantronics Headset CS60, there can be occur sporadically error’s when you are answer a call with the button at the Headset. This happens if you make two calls directly fast after each other
 +
}}
 +
 +
== Since Release [[optiPoint 410/420 Release Notes#V5 R5.5.0|V5 R5.5.0]] or later ==
 +
 +
{{Warning|
 +
Upon the following hardware revisions the optiPoint 4x0 advance does not longer have an USB-port. This hardware revision must be used with software version optiPoint 410/420 V5 R5.6.0  (or higher).
 +
* S30817-S7204-A101-26 (optiPoint 410 advance arctic)
 +
* S30817-S7204-A107-31 (optiPoint 410 advance mangan)
 +
* S30817-S7207-A101-26 (optiPoint 420 advance arctic)
 +
* S30817-S7207-A107-24 (optiPoint 420 advance mangan)
 +
}}
 +
 +
== Since Release [[optiPoint 410/420 Release Notes#V5 R6.1.0|V5 R6.1.0]] or later ==
 +
 +
{{Warning|
 +
Starting with the Version V5 R6.1.0, you will get new hardware. With following part number:
 +
*S30817-S7202-A101-27 OP410 ECONOMY ARC
 +
*S30817-S7202-A107-33 OP410 ECONOMY MAN
 +
*S30817-S7203-A101-29 OP410 STANDARD ARC
 +
*S30817-S7203-A107-37 OP410 STANDARD MAN
 +
*S30817-S7204-A101-28 OP410 ADVANCE ARC
 +
*S30817-S7204-A107-33 OP410 ADVANCE MAN
 +
*S30817-S7207-A101-28 OP420 ADVANCE ARC
 +
*S30817-S7207-A107-26 OP420 ADVANCE MAN
 +
*S30817-S7209-A101-16 OP420 ECONOMY ARC
 +
*S30817-S7209-A107-17 OP420 ECONOMY MAN
 +
*S30817-S7210-A101-17 OP420 ECO PLUS ARC
 +
*S30817-S7210-A107-18 OP420 ECO PLUS MAN
 +
*S30817-S7211-A101-17 OP420 STANDARD ARC
 +
*S30817-S7211-A107-18 OP420 STANDARD MAN
 +
*S30817-S7212-A101-20 OP410 ECO PLUS ARC
 +
*S30817-S7212-A107-20 OP410 ECO PLUS MAN
 +
 +
IMPORTANT!! Introduced with the Version V5 R6.1.0 you will find new Displays (see section 5.1)
 +
There are some points that you need to mind:
 +
*You can only use the Software Version V5 R6.1.0 or later
 +
*You need to use the new Netboot V4.05 or later
 +
*If you exchange the Display on a old phone you need to use the these Version
 +
}}
 +
 +
 +
 +
{{SeeAlso optiPoint 410/420}}

Latest revision as of 14:04, 17 December 2014

The support for this product has been discontinued!
Please visit Devices to get further information about the current product portfolio.


Information to V5.1 of the optiPoint 410/420 CorNet-IP (HFA) phone family.

General Info for all Releases

If there where seen Link Flaps on the Ethernet Switch when the Phone is powered off, please try to configure the Switch to 100 Mbit full- or half- duplex static. In some cases this error was solved with this configuration.
  • Payload Security is only possible with the optiPoint 410/420 eco+/std/adv
  • G.722 CoDec is used with DMC (Direct Media Connection) between two optiPoint 4X0 IP phones only (DMC feature must be activated).
  • A call via Gateway never uses G.722.
  • If “High Quality pref.” is entered, G.722 calls to other OP4X0 or OpenStage HFA are possible, but only G.711 calls to other phones. Because of this the users get a different impression of quality.
  • It is highly recommended to deactivate both VAD (Voice Activity Detection) and Silence Suppression features.
  • To upgrade via NetBoot the Key 3 have to be pressed while powering up the phone until the phone starts to load the image.
  • Netboot Upgrade via Remote is only possible with V5 R1.33.0 or later.
  • DHCP Leasetime: The recommended minimum leasetime is 8min as the RFC2131 is quite unclear about how long a leasetime should be as a minimum.
    See section 4.4.5 Reacquisition and expiration
    "In both RENEWING and REBINDING states, if the client receives no response to its DHCPREQUEST message, the client SHOULD wait one-half of the remaining time until T2 (in RENEWING state) and one-half of the remaining lease time (in REBINDING state), down to a minimum of 60 seconds, before retransmitting the DHCPREQUEST message."

Since Release V5 R1.33.0 or later

At the moment there is a level 1 priority Bug at the HiPath DLS in combination with the NEW Version string.
At the Software Deployment in the DLS you can’t update more than one phone at the same time.
This Bug is solved with the HiPath DLS V1.0 R1.27.0 (HI-DLS.10.199.41) version.

Since Release V5 R1.34.0 or later

  • Now the Software comprised the AGP (Application Generic Platform) functionality including XML Applications support.
    This functionality will be only released project specific for prototype of corresponding applications.
    The AGP feature works only with a optiPoint application module connected.

Since Release V5 R1.35.0 or later

To make a bulk deployment of optiPoint 410/420 adopting the new Version String Vx[.y] Rm.f.h scheme through the DLS tool it's mandatory to use HiPath DLS V1.0 R1.27.0 (HI-DLS.10.199.41) version or higher.

Since Release V5 R1.35.1 or later

  • Used RTP port base from Port 5004 to 5013.
    Now the ports are used from the lowest configured Port to the highest.
    Example:
5004 for RTP of the Master channel to the HG3530.
5005 for RTCP of the Master channel to the HG3530.
5006 for RTP the Slave channel to B partner.
5007 for RTCP the Slave channel to B partner.

Since Release V5 R2.36.4 or later

Since Release V5 R4.6.0 or later

  • Implementation of the RQ00026068/RQ00026067. EAPOL-Logoff function is now working without activation of IEEE 802.1x.
Security Step 1 is only supported with Hardware that has a equal or less Part Number then following:
  • optiPoint 410 entry S30817-S7201-A101-25 Arctic
  • optiPoint 410 entry S30817-S7201-A107-32 Mangan
  • optiPoint 410 economy S30817-S7202-A101-25 Arctic
  • optiPoint 410 economy S30817-S7202-A107-31 Mangan
  • optiPoint 410 eco plus S30817-S7212-A101-19 Arctic
  • optiPoint 410 eco plus S30817-S7212-A107-19 Mangan
  • optiPoint 410 standard S30817-S7203-A101-27 Arctic
  • optiPoint 410 standard S30817-S7203-A107-35 Mangan
  • optiPoint 410 advance S30817-S7204-A101-27 Arctic
  • optiPoint 410 advance S30817-S7204-A107-32 Mangan
  • optiPoint 420 eco S30817-S7209-A101-15 Arctic
  • optiPoint 420 eco S30817-S7209-A107-16 Mangan
  • optiPoint 420 eco plus S30817-S7210-A101-16 Arctic
  • optiPoint 420 eco plus S30817-S7210-A107-17 Mangan
  • optiPoint 420 standard S30817-S7211-A101-16 Arctic
  • optiPoint 420 standard S30817-S7211-A107-17 Mangan
  • optiPoint 420 adv. S30817-S7207-A101-25 Arctic
  • optiPoint 420 adv. S30817-S7207-A107-23 Mangan

Since Release V5 R5.2.0 or later

  • Security Step 1 is not supported in this Bind, because of the support for SPE
  • The dowload capability for JAVA midlets is not longer supported. Do to the fact that Java midlets are out of support
  • For Mobile HFA please use the following Patch sets at the H4K - s20439 (H30160); s20419 (H30910); s20440 (H30966).

Since Release V5 R4.7.0 or later

IMPORTANT!! There are new restrictions for the 802.1x feature

For the certificate creation the are restrictions for the max. size of certificate.

  • Phone certificate the max. size is 2048 bytes.
  • Radius & root certificate the max. size is 4096 bytes.

V5 R5.4.0

If you are using the plantronics Headset CS60, there can be occur sporadically error’s when you are answer a call with the button at the Headset. This happens if you make two calls directly fast after each other

Since Release V5 R5.5.0 or later

Upon the following hardware revisions the optiPoint 4x0 advance does not longer have an USB-port. This hardware revision must be used with software version optiPoint 410/420 V5 R5.6.0 (or higher).

* S30817-S7204-A101-26 (optiPoint 410 advance arctic)
* S30817-S7204-A107-31 (optiPoint 410 advance mangan)
* S30817-S7207-A101-26 (optiPoint 420 advance arctic)
* S30817-S7207-A107-24 (optiPoint 420 advance mangan)

Since Release V5 R6.1.0 or later

Starting with the Version V5 R6.1.0, you will get new hardware. With following part number:

  • S30817-S7202-A101-27 OP410 ECONOMY ARC
  • S30817-S7202-A107-33 OP410 ECONOMY MAN
  • S30817-S7203-A101-29 OP410 STANDARD ARC
  • S30817-S7203-A107-37 OP410 STANDARD MAN
  • S30817-S7204-A101-28 OP410 ADVANCE ARC
  • S30817-S7204-A107-33 OP410 ADVANCE MAN
  • S30817-S7207-A101-28 OP420 ADVANCE ARC
  • S30817-S7207-A107-26 OP420 ADVANCE MAN
  • S30817-S7209-A101-16 OP420 ECONOMY ARC
  • S30817-S7209-A107-17 OP420 ECONOMY MAN
  • S30817-S7210-A101-17 OP420 ECO PLUS ARC
  • S30817-S7210-A107-18 OP420 ECO PLUS MAN
  • S30817-S7211-A101-17 OP420 STANDARD ARC
  • S30817-S7211-A107-18 OP420 STANDARD MAN
  • S30817-S7212-A101-20 OP410 ECO PLUS ARC
  • S30817-S7212-A107-20 OP410 ECO PLUS MAN

IMPORTANT!! Introduced with the Version V5 R6.1.0 you will find new Displays (see section 5.1) There are some points that you need to mind:

  • You can only use the Software Version V5 R6.1.0 or later
  • You need to use the new Netboot V4.05 or later
  • If you exchange the Display on a old phone you need to use the these Version


See also