This information describes distinctions while upgrading optiPoint 410/420 phones to SIP V6.0.
+
This information describes distinctions while upgrading optiPoint 410/420 S phones to [[optiPoint 410/420 S general information to SIP V6.0|optiPoint 410/420 SIP V6.0]] Application Software.
For common upgrade procedure (download application) refer to [[Firmware upgrade optiPoint 410/420 S phones]].
 
  
The SIP V6.0 firmware can be loaded onto the phone via [[FTP]] (if supported by the software being upgraded from):
+
For common upgrade procedure (download application) refer to [[optiPoint 410/420 S firmware upgrade procedure]].
* Via the [[WBM|Web-based management]] (supported by all).
 
* Via the phone's local user interface (not supported by 410 entry S).
 
* Via [[Deployment Service]] (supported by V4.1.20 onwards and V5.0.x and V6.0.x).
 
  
== Migration from CorNet IP ([[HFA]]) to SIP ==
+
For migration from CorNet IP ([[HFA]]) to SIP Application Software see [[optiPoint 410/420 CorNet IP (HFA) to SIP migration]].
  
See [[Migrate optiPoint 410/420 CorNet IP (HFA) phones to SIP]].
+
== Possibilities of Upgrading ==
  
== Upgrading from SIP V5.0.15 or earlier ==
+
The optiPoint 410/420 SIP V6.0 Application Software can be uploaded on the phone via [[FTP]] (if supported by the software being upgraded from):
In SIP V6.0 the [[VLAN]] discovery default settings are set to [[DHCP]]. This may cause problem, when the phone was configured for manual VLAN discovery.  
+
* Via the [[WBM]] interface (supported by all phone models)
# Change the phone's VLAN discovery setting to <code>DHCP</code>, then back to <code>manual</code>. This will store the setting in the phone’s database and the default value is not used.
+
* Via the phone's local user interface (not supported by 410 entry S that hasn't the display)
# Reboot the phone.
+
* Via [[DLS|HiPath DLS]] application (supported by V4.1.20 onwards, V5.0.x, V6.0.x and V7)
# Upgrade phone to SIP V6.0 (see [[Firmware upgrade optiPoint 410/420 S phones]]).
+
 
 +
== Upgrading from SIP V5.0.15 or earlier versions ==
 +
 
 +
In optiPoint 410/420 SIP V6.0 Application Software the [[VLAN]] discovery default setting is set to [[DHCP]].
 +
 
 +
This may cause problem, when the phone was configured for manual VLAN discovery.
 +
# Change the phone's [[VLAN]] discovery setting to <code>DHCP</code>, then back to <code>manual</code>, this action will store the setting in the phone’s database and the default value is not used
 +
# Reboot the phone
 +
# Upgrade phone to [[SIP]] V6.0 (see [[optiPoint 410/420 S firmware upgrade procedure]])
 +
 
 +
== Upgrading from SIP V4.1.15 or earlier versions ==
 +
 
 +
Note that [[QoS]] default settings are now set to <code>ON</code> (both on L2 and L3 layers).
 +
 
 +
This may cause problem when the phone sends tagged frames and your network devices can’t handle these tagged frames.
 +
In this case, we suggest the following workaround, before performing the upgrade:
 +
# Change the phone's [[QoS]] L2 layer setting to <code>ON</code>, then back to <code>OFF</code> and reboot the phone, this action will store the setting in the phone’s database and the default value is not used.
 +
 
 +
{{SeeAlso optiPoint 410/420 S}}
  
 
[[Category:optiPoint]]
 
[[Category:optiPoint]]
 
[[Category:Configuration]]
 
[[Category:Configuration]]

Latest revision as of 08:39, 11 August 2011

This information describes distinctions while upgrading optiPoint 410/420 S phones to optiPoint 410/420 SIP V6.0 Application Software.

For common upgrade procedure (download application) refer to optiPoint 410/420 S firmware upgrade procedure.

For migration from CorNet IP (HFA) to SIP Application Software see optiPoint 410/420 CorNet IP (HFA) to SIP migration.

Possibilities of Upgrading

The optiPoint 410/420 SIP V6.0 Application Software can be uploaded on the phone via FTP (if supported by the software being upgraded from):

  • Via the WBM interface (supported by all phone models)
  • Via the phone's local user interface (not supported by 410 entry S that hasn't the display)
  • Via HiPath DLS application (supported by V4.1.20 onwards, V5.0.x, V6.0.x and V7)

Upgrading from SIP V5.0.15 or earlier versions

In optiPoint 410/420 SIP V6.0 Application Software the VLAN discovery default setting is set to DHCP.

This may cause problem, when the phone was configured for manual VLAN discovery.

  1. Change the phone's VLAN discovery setting to DHCP, then back to manual, this action will store the setting in the phone’s database and the default value is not used
  2. Reboot the phone
  3. Upgrade phone to SIP V6.0 (see optiPoint 410/420 S firmware upgrade procedure)

Upgrading from SIP V4.1.15 or earlier versions

Note that QoS default settings are now set to ON (both on L2 and L3 layers).

This may cause problem when the phone sends tagged frames and your network devices can’t handle these tagged frames. In this case, we suggest the following workaround, before performing the upgrade:

  1. Change the phone's QoS L2 layer setting to ON, then back to OFF and reboot the phone, this action will store the setting in the phone’s database and the default value is not used.

See also