Views

optiPoint 410/420 S handle internal phone traces

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Revision as of 10:59, 7 November 2008 by Horemu (talk | contribs) (Deactivate internal phone traces)
Jump to: navigation, search

Sometimes development is not able to pinpoint a problem with network traces only. It could happen that the message flow is correct but the phone behavior is not as it should be. For those cases the phones are able to trace internal processes that show the development what is going wrong.

The steps for activating / reading out / deactivating those traces are mostly the same. With this HowTo in hands the requester must only define which traces he needs.

Pre-Conditions

Ensure that the phone is configured with a working SNTP server to have the correct time available in the traces.

  • If no SNTP server is available, ensure that the correct time is configured manually.

If it is asked to deliver the internal phone traces in combination with some other traces (e.g. Wireshark) it is necessary that the trace-pc has configured the same SNTP server as the phone.

  • If no SNTP server is available, ensure that you’ve configured the same time on all tracing devices.

Activate internal phone traces

Log-in to the WBM as administrator.

oPSIP-IntlPhnTrc FaultInvestigation.jpg

Select the Fault Investigation menu.

oPSIP-IntlPhnTrc TraceConfiguration.jpg

Select Trace Configuration.

oPSIP-IntlPhnTrc Tracing.jpg

Choose File as Trace Output.

Set the timeout to 9999 minutes (max).

Activate the checkbox for “Automatic clear before start”.

oPSIP-IntlPhnTrc ApplicationStreams.jpg

Choose / set the parameter as seen on the picture above if nothing else has been requested.

Click on the Submit button.

Trace logging is now activated and all relevant activities of the phone will be saved (till the trace file is full – oldest messages will be overwritten.

Read out the internal phone traces

It is recommended to wait ~3 minutes before you read out the phone internal traces. This will ensure that all log messages are written to the file and no messages are lost.

Log-in to the WBM as administrator.

oPSIP-IntlPhnTrc FaultInvestigation.jpg

Select the Fault Investigation menu.

oPSIP-IntlPhnTrc TraceView.jpg

Select Trace View.

oPSIP-IntlPhnTrc TraceFileStream.jpg

Select File as Trace Source.

Choose one of the activated traces (usually Error, SIP UI, SIP Call Control and SIP Signalling).

Click on Submit.

The selected stream is now displayed in your browser.

oPSIP-IntlPhnTrc LogFile.jpg

Copy all content between the grey Buttons into a text-file.

Save it to your computer, using a clear name (e.g. for each stream a separate file: Error.txt; SIP UI.txt …).

Repeat the steps above till you have copied all traces to separate files.

Deactivate internal phone traces

Log-in to the WBM as administrator.

oPSIP-IntlPhnTrc FaultInvestigation.jpg

Select the Fault Investigation menu.

oPSIP-IntlPhnTrc TraceView.jpg

Select Trace View.

oPSIP-IntlPhnTrc Submit.jpg

Just click on the Submit button (It doesn’t matter which stream you select).

The selected stream is now displayed in your browser.

oPSIP-IntlPhnTrc StopTracing.jpg

Push the Stop tracing button.

By clicking this button all activated traces will automatically be deactivated. The SIP UDP Trace is a separate trace and will not be deactivated.

It is recommended to deactivate the traces after they have been saved to disburden the phone as much as possible.