Views

Difference between revisions of "optiPoint 410/420 Firmware and Application software upload with NetBoot server"

The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.

Jump to: navigation, search
 
(22 intermediate revisions by 5 users not shown)
Line 1: Line 1:
<div class="breadcrumb">
+
{{Breadcrumb|0|0|{{dev-en}}|optiPoint|optiPoint 410/420 S}}
{{up}} [[How To]] | {{de}} [[Setting up optiPoint 410/420 telephones with NetBoot]]
 
</div>
 
In order to copy ([[SIP]] or [[HFA]]) software to a telephone in the optiPoint 410/420 family, you need a [[NetBoot]] server installed on a PC.
 
The Netboot server is generally required for a download if:
 
* The firmware (also netboot) of the telephone is no longer up to date,
 
* The telephone no longer boots and therefore is no longer accessible via the Web interface or
 
* The application software is to be updated but the telephone is not accessible via the usual user interfaces.
 
  
The following can be transferred:
+
{{Discontinued|en|Devices}}
* The current or replacement application software with the extension <code>.fli</code> (e.g. <code>410adv_SIP_6_0_55.fli</code>) and
 
* A new NetBoot version of the telephone firmware is applicable (e.g. <code>netboot201.fli</code> for SIP or <code>netboot308.fli</code> for HFA).
 
 
 
It is possible to overwrite both SIP software with HFA software and HFA software with SIP software.
 
 
 
== Prerequisite ==
 
 
 
You need modules with at least the hardware versions listed under [[SIP V6.0 optiPoint compatibility]] in order to update telephones in the optiPoint 410/420 famiily for use under SIP V6.0. HFA updates (firmware and application) can be performed on all model versions of the optiPoint 410/420 family.
 
 
 
You need the following to complete the download:
 
* A PC with a[[LAN]] connection,
 
* The relevant from the optiPoint 410/420 family,
 
* A [[TFTP]] server (e.g. the 3CDaemon from [http://www.3com.com/ 3Com]),
 
* The[[NetBoot]] server program for the PC (you will find the program on the [https://enterprise-businessarea.siemens.com SEBA] Web portal under the relevant heading - Login required) and
 
* The data for installation (see above).
 
 
 
== Preparation ==
 
 
 
* Install the NetBoot and the[[TFTP]] server on the PC, if this has not already been done.
 
* Fetch the files to be transferred or have them at the ready (you will find the data in the [https://enterprise-businessarea.siemens.com SEBA] Web portal under the relevant heading - Login required).
 
 
 
== Configuring the [[TFTP]] server ==
 
 
 
Start the TFTP server. Click '''Configure TFTP Server''', go to the '''TFTP Configuration''' tab and specify the directory under '''Upload/Download directory''' in which the files for installation are stored.
 
 
 
[[Image:10 configure TFTP server.png|thumb|left|Konfiguration TFTP-Server|300px]]<br clear="left">
 
 
 
== Configuring the Netboot server==
 
 
 
Start the NetBoot server. You will see the following window:
 
 
 
[[Image:NetBoot-start.gif|thumb|left|Main window of NetBoot server|300px]]<br clear="left">
 
 
 
=== Adding an entry ===
 
 
 
Click '''Add Entry''' in the main window in the '''Database''' menu. The following dialog is displayed:
 
 
 
[[Image:NetBoot-addentr.gif|thumb|left|Details of telephone properties|300px]]<br clear="left">
 
 
 
Provide the following information:
 
* '''Alias''': Enter a freely definable alias name for this entry, for example <code>optiPoint 410 economy plus S</code>.
 
* '''MAC Address''' > '''Single Address''': Enter the MAC address of the phone.<br>The MAC address is imprinted on the underside of the optiPoint phone as '''Ser.No.''':[[Image:op-macaddr.jpg|thumb|left|optiPoint MAC address]]<br clear="left">
 
* Tick '''Active'''.
 
* '''IP Address''' > '''Fixed Address''': Enter the IP address the phone is to have after it has been started in Netboot mode.
 
* '''Boot File''': Specify the file that is to be loaded. This can either be an application or a new NetBoot version, for example: <code>410adv_SIP_6_0_58.fli</code> or <code>netboot201.fli</code>.
 
 
 
Click'''OK''' to apply the changes.
 
 
 
=== Defining general properties ===
 
 
 
Click the '''Properties''' option in the main window in the '''Database''' menu. The following dialog box opens:
 
 
 
[[Image:NetBoot-propgeneral.gif|thumb|left|Details of netmask|300px]]<br clear="left">
 
 
 
* '''Network Mask''': Specify the subnet mask valid in your [[LAN]].
 
 
 
Click '''Firmware Update'''. The following dialog is displayed:
 
 
 
[[Image:NetBoot-propupdate.gif|thumb|left|Details of server IP and path|300px]]<br clear="left">
 
 
 
* '''TFTP Server IP Address''': Specify the IP address of the TFTP server.
 
* '''Boot Image Search Path''': Specify a path for the file if applicable, starting from the server root.
 
 
 
Click '''OK''' to apply the changes.
 
 
 
All preparations are now complete. You can now perform the update.
 
 
 
== Executing the application or NetBoot update ==
 
 
 
Make sure that the [[TFTP]] server and the [[NetBoot]] server are started on the PC.
 
 
 
If power is supplied to the phone via a power supply unit:
 
* Connect the phone to the LAN.
 
* Hold down the [[Image:opk-3.png]] key on the phone and and connect the power supply for the phone.
 
 
 
If power is supplied to the phone via LAN ([[PoE]]):
 
* Hold down the [[Image:opk-3.png]] key on the phone and and connect the phone to the LAN.
 
 
 
The phone searches for the NetBoot server, loads the update file from the [[TFTP]] server and then boots with the new application or firmware (NetBoot software).
 

Latest revision as of 08:26, 18 December 2014


The support for this product has been discontinued!
Please visit Devices to get further information about the current product portfolio.