OpenStage Hardware Changes and necessary Software Versions
The Wiki of Unify contains information on clients and devices, communications systems and unified communications. - Unify GmbH & Co. KG is a Trademark Licensee of Siemens AG.
This article or section is currently under construction. In order to avoid editing conflicts, please wait until this message is removed or contact the author (Horemu (talk) 10:43, 11 December 2012 (CET)). |
Phones and start of mass production
HW Changes[1] | OS60 TDM |
OS80 TDM |
OS15 SIP |
OS15 HFA |
OS15G SIP/HFA |
OS40 SIP/HFA |
OS40 US SIP |
OS40G SIP/HFA |
OS40G US SIP |
OS60 SIP/HFA |
OS60G SIP/HFA |
OS80 SIP/HFA |
OS80G SIP/HFA |
Start[2] |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
X | 13.10.2009 | |||||||||||||
X | 04.06.2009 | |||||||||||||
X | X | X | X | X | X | X | X | X | X | X | X | X | Text | |
OpenStage 40 Display driver change for FPK's from polling to interupt mode | X | X | X | X | X | X | X | X | X | X | X | X | X | Text |
Change display driver for OpenStage 80 VGA Display | X | X | X | X | X | X | X | X | X | X | X | X | X | Text |
Change Bluetooth driver | X | X | X | X | X | X | X | X | X | X | X | X | X | Text |
X | X | X | X | X | X | X | X | X | X | X | X | X | Text | |
Change LLDP-MED message for OpenStage 15 HFA | X | X | X | X | X | X | X | X | X | X | X | X | X | Text |
MMI-Board (change driver for Mode Keys and Slider) | X | X | X | X | X | X | X | X | X | X | X | X | X | Text |
New QVGA-Display (change driver) green IT | X | X | X | X | X | X | X | X | X | X | X | X | X | Text |
OpenStage 15 Gigabit Version SIP/HFA (new phone) | X | X | X | X | X | X | X | X | X | X | X | X | X | Text |
Comments, revisions and effects
HW Changes[1] | Comments[2] | HW Revision[3] | Effects[4] |
---|---|---|---|
for device manufacturing released phone software:
|
S30817-S7401-D501-4 (OpenStage 15 HFA iceblue) S30817-S7401-D503-4 (OpenStage 15 HFA lava) |
If the phones operate with lower software versions than the phone does not oprate. Note: even if a lower software version was downloaded into the phone, an upgrade to the necessary software version is possible (e.g. DLS) | |
for device manufacturing released phone software:
|
S30817-S7401-A501-6 (OpenStage 15 SIP iceblue) S30817-S7401-A503-3 (OpenStage 15 SIP lava) | ||
for device manufacturing released phone software:
|
S30817-S7402-D101-16 (OpenStage 40 HFA ice blue) S30817-S7402-D103-17 |
If the phones operate with lower software versions than the display and wireless headset do not work. Note: even if a lower software version was downloaded into the phone, an upgrade to the necessary software version is possible (e.g. DLS) | |
OpenStage 40 Display driver change for FPK's from polling to interupt mode | X | X | Text |
Change display driver for OpenStage 80 VGA Display | X | X | Text |
Change Bluetooth driver | X | X | Text |
X | X | Text | |
Change LLDP-MED message for OpenStage 15 HFA | X | X | Text |
MMI-Board (change driver for Mode Keys and Slider) | X | X | Text |
New QVGA-Display (change driver) green IT | X | X | Text |
OpenStage 15 Gigabit Version SIP/HFA (new phone) | X | X | Text |