{{Discontinued|en|Devices}}
  
* {{en}} {{File-DL|How_to_upgrade_to_a_SIP_version_form_a HFA_version.pdf|pdf}}
+
OpenScape Business supports the connection of optiPoint WL2 devices with SIP protocol stack.<br>
 +
OptiPoint WL2 devices with HFA protocol can be reused, if the HFA protocol stack is replaced by SIP protocol stack. <br>
 +
The replacement procedure is described within:
  
 +
* {{en}} {{File-DL|How_to_upgrade_to_a_SIP_version_from_a HFA_version|pdf}}
  
 +
The appropriate SW image is provided by the SW Downlad Server (SWS), which can be accessed via the Unify Business Area {{SEBA}}.<br>
 +
The document above has been copied out the relase note of the of optipoint WL2 SW. It is recommended to check, if the information has been updated within the release note of the downloaded SW version.
  
The following procedure is needed to upgrade an optiPoint WL2 professional (HFA version to an optiPoint WL2 professional S (SIP version).
+
'''Please note:'''<br>
The upgrade needs an updated factory data file system in the phone in order to work correctly.To get these upgrade to your phone there are a specialized intermediate software version. For safety reasons please save former settings over WBM backup. Therefore the software upgrade is done in two steps according to the following description.
+
All user data within optiPoint WL2 device are lost after protocol replacement.<br>
 
+
optiPoint WL2 on base of SIP or HFA offer a different feature set.
1. Upgrade to the intermediate version prep70_39.img
 
 
 
Install first the intermediate version prep70_39.img via the common way either by WBM or by DLS. You can see the progress of this upgrade in the phone display. When the phone starts up with this version the factory data file system content is set to the default values of a standard SIP version and the default ringer tones and images are copied to the data files. The following message will be displayed:
 
* Temp. SW only!
 
* Please Update!
 
and can be confirmed with "OK". It is not necessary to confirm it for the upgrade to the final version.
 
 
 
2. Finalize the upgrade to the final version with a standard SW file e.g. swup_70-000-052
 
 
 
Finalize the upgrade procedure with a standard update file e.g. swup_70-000-052
 
 
 
Because of security reasons are all settings and user data not changed during this upgrade.
 
 
 
The activation of the default phone settings have to be carried out manually via WBM or DLS.
 
 
 
If you use WBM please use:
 
 
 
System Settings - Reset User Data - User Settings Clear
 
 
 
or
 
 
 
Factory Reset - Restore the factory defaults
 
 
 
(Caution! All user data will be lost)
 

Latest revision as of 11:32, 3 August 2015


The support for this product has been discontinued!
Please visit Devices to get further information about the current product portfolio.

OpenScape Business supports the connection of optiPoint WL2 devices with SIP protocol stack.
OptiPoint WL2 devices with HFA protocol can be reused, if the HFA protocol stack is replaced by SIP protocol stack.
The replacement procedure is described within:

The appropriate SW image is provided by the SW Downlad Server (SWS), which can be accessed via the Unify Business Area Partner Portal.
The document above has been copied out the relase note of the of optipoint WL2 SW. It is recommended to check, if the information has been updated within the release note of the downloaded SW version.

Please note:
All user data within optiPoint WL2 device are lost after protocol replacement.
optiPoint WL2 on base of SIP or HFA offer a different feature set.